In a clinical application, a method for an examination of a vibratory sense is not very objective and it depends on an active cooperation of a patient, which cannot be achieved in every situation. The aim of this research is to define parameters of an evoked potentials method with a vibratory stimulation technique which would establish reliable and repeatable results applicable in a clinical usage. During the research, different experimental conditions were performed (different methods of stimulation, different stimulation frequencies, different stimulus durations, different areas of stimulation). Presented results confirm the initial assumption that it is possible to detect reliable and repeatable cortical potentials evoked by the vibratory stimulation. Characteristic shapes and spatiotemporal distributions of evoked responses are established. Optimal stimulation parameters are defined as a prelude for a future research.%U kliničkoj uporabi, metoda ispitivanja dubokog osjeta pomoću vibracija nije objektivna I zahtijeva aktivnu suradnju pacijenta što u brojnim situacijama nije moguće. Svrha ovog istraživanja je definirati parametre metode evociranih potencijala pobuđenih vibracijskom stimulacijom primjenjive u kliničkoj uporabi, koja će davati pouzdane I ponovljive rezultate. Tijekom ispitivanja, primijenjeni su različiti eksperimentalni uvjeti (različite tehnike stimulacije, različite frekvencije stimulacije, različita trajanja stimulacije, različita područja stimuliranja). Rezultati potvrđuju početnu pretpostavku da je moguće detektirati pouzdane I ponovljive kortikalne potencijale pobuđene vibracijskom stimulacijom. Utvrđeni su karakteristični valni oblici evociranih odgovora I njihove prostorno-vremenske karakteristike. Optimalni stimulacijski parametri su definiriani kao podloga za buduća istraživanja.
机译:在临床应用中,用于检查振动感的方法不是很客观,并且取决于患者的积极配合,这在每种情况下都无法实现。这项研究的目的是使用振动刺激技术来定义诱发电位方法的参数,该参数将建立适用于临床的可靠和可重复的结果。在研究过程中,执行了不同的实验条件(不同的刺激方法,不同的刺激频率,不同的刺激持续时间,不同的刺激区域)。提出的结果证实了最初的假设,即有可能检测到由振动刺激引起的可靠和可重复的皮质电位。建立了诱发反应的特征形状和时空分布。最佳刺激参数被定义为未来研究的序幕。%Ukliničkojuporabi,metoda ispitivanja dubokog osjetapomoćuvibracija nije objektivna I zahtijeva aktivnu suradnju pacijentaštou brojnim situacijama nijemoguće。我的定义是绝对的参数,是可能的,但需要重新修改。 Tijekom ispitivanja,primijenjeni surazličitieksperimentalni uvjeti(različitetehnike stimulacije,različitefrekvencije stimulacije,različitatrajanja stimulacije,različitapodručjastimuliranja)。我的建议是我的建议,我建议的建议是。乌克兰国务卿伊维希拉·普罗斯托尔诺-弗雷门斯科·卡拉特里斯蒂克。最优化参数设置,最后确定。

著录项

  • 来源
    《Automatika 》 |2011年第1期| p.31-38| 共8页
  • 作者单位

    University of Zagreb, Trg Marsala Tita 14, HR-10000 Zagreb, Croatia;

    University of Zagreb, Trg Marsala Tita 14, HR-10000 Zagreb, Croatia;

    Department of Electronic Systems and Information Processing, Faculty of Electrical Engineering and Computing, Unska 3, HR-10000 Zagreb, Croatia;

    Department of Neurology, University Hospital Zagreb, Kispaticeva 12, HR-10000 Zagreb, Croatia;

    Department of electronics, microelectronics, computer and intelligent systems, Faculty of Electrical Engineering and Computing, Unska 3, HR-10000 Zagreb, Croatia;

    Department of Neurology, University Hospital Zagreb, Kispaticeva 12, HR-10000 Zagreb, Croatia;