首页> 外文期刊>Australian Journal of Structural Engineering >Seismic response control of base-isolated buildings using tuned mass damper
【24h】

Seismic response control of base-isolated buildings using tuned mass damper

机译:使用调谐质量阻尼器的底座建筑物的地震反应控制

获取原文
获取原文并翻译 | 示例
           

摘要

ABSTRACT Earthquake response mitigation of base-isolated (BI) buildings with a tuned mass damper (TMD) is investigated. Two-dimensional reinforced concrete buildings having multiple degrees of freedom are numerically modelled. The placement of a TMD is varied on different floor levels and the building response under earthquake excitations is studied. The laminated rubber bearing (LRB), lead rubber bearing (N-Z), friction pendulum system and resilient-friction base isolator (R-FBI) are used as isolation systems for the buildings with 5, 10 and 15 floor levels. Newmark’s step-by-step method of integration is used for solving differential equations of motion of the coupled buildings. Installation of a TMD at different story of the BI buildings mitigates the acceleration at the top level and displacement at bearings. It is found that at increased time period of the isolators the effectiveness of the TMD is reduced. Further, for low-rise buildings, the placement of TMD has no significant role in reducing the response of the buildings. However, the efficiency of TMD placement is more noticeable for buildings with a larger number of stories.
机译:摘要调查了带有调谐质量阻尼器(TMD)基地隔离(BI)建筑物的地震反应减缓。具有多程度自由度的二维钢筋混凝土建筑在数值上进行了数值模拟。 TMD的放置在不同的楼层水平上变化,研究了地震激励下的建筑物反应。层压橡胶轴承(LRB),铅橡胶轴承(N-Z),摩擦摆动系统和弹性 - 摩擦基座隔离器(R-FBI)用作具有5,10和15楼层的建筑物的隔离系统。纽马克的集成级别方法用于求解耦合建筑物的运动的微分方程。在双层建筑物的不同故事中安装TMD减轻了轴承顶层和位移的加速度。发现在隔离器的增加期间,TMD的有效性降低。此外,对于低层建筑,TMD的放置在减少建筑物的响应方面没有显着作用。然而,TMD放置的效率对于具有更大故事的建筑物更加明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号