Although arc suppression coil systems are able to detected high impedance ground faults by monitoring the neutral voltage, there are other system abnormalities which can also cause a change in the neutral voltage. The causes of abnormal neutral voltages in arc suppression coil systems are analysed and criteria are developed to differentiate between them based on the phase angle and magnitude of the neutral voltage. Using the criteria developed in this paper, modern computerised protection systems will be able to automatically take appropriate action based on the type of system abnormality, immediately, when a system abnormality occurs.
机译:尽管消弧线圈系统能够通过监视中性点电压来检测高阻抗接地故障,但还有其他系统异常也可能导致中性点电压发生变化。分析了消弧线圈系统中中性电压异常的原因,并根据中性电压的相角和大小来确定判别标准。使用本文开发的标准,当系统异常发生时,现代的计算机保护系统将能够根据系统异常的类型自动采取适当的措施。