After the Fukushima accident, increasing interest has been raised in passive safety systems that maintain the integrity of the containment building. To improve the reliability and safety of nuclear power plants, long-term passive cooling concepts have been developed for advanced reactors. In a previous study, the proposed design was based on an ordinary cylindrical Two-Phase Closed Thermosyphon (TPCT). The exact assembly size and number of TPCTs should be elaborated upon through accurate calculations based on experiments. While the ultimate goal is to propose an effective MPHP design for the PCCS and experimentally verify its performance, a TPCT assembly that was manufactured based on the conceptual design in this paper was tested.
机译:福岛事故发生后,人们越来越关注能够保持安全壳建筑完整性的被动安全系统。为了提高核电厂的可靠性和安全性,已经为高级反应堆开发了长期被动冷却概念。在先前的研究中,建议的设计基于普通的圆柱形两相封闭式热虹吸管(TPCT)。应通过基于实验的精确计算来详细说明TPCT的确切组装尺寸和数量。尽管最终目标是为PCCS提出有效的MPHP设计并通过实验验证其性能,但还是对基于本文概念设计制造的TPCT组件进行了测试。

著录项

  • 来源
    《ATW》 |2017年第6期|413-418|共6页
  • 作者

    Nam Kyung Ho; Kim Sang Nyung;

  • 作者单位

    Korea Atom Energy Res Inst, 111 Daedeok Daero 989Beon Gil, Daejeon, South Korea;

    Kyung Hee Univ, 1732 Deogyeong Daero, Yongin, Gyeonggi Do, South Korea;

  • 收录信息 美国《科学引文索引》(SCI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号