The results of an experimental investigation of heat transfer through a gap filled with a steam-water mixture are presented. It is shown that heat transfer through such a gap is considerably different from heat transfer through a solid wall with similar geometry. The heat flux through a gap where steam condenses is almost independent of the temperature of the warming medium, but the proximity of the 'cold' wall temperature to the saturation temperature does affect it.
机译:给出了通过充满蒸汽-水混合物的间隙传热的实验研究结果。示出了通过这种间隙的热传递与通过具有相似几何形状的实心壁的热传递显着不同。通过蒸汽冷凝的间隙的热通量几乎与变暖介质的温度无关,但是“冷”壁温度接近饱和温度确实会影响它。

著录项

  • 来源
    《Atomic Energy》 |2014年第5期|294-299|共6页
  • 作者单位

    Dollezhal Research and Development Institute of Power Engineering (NIKIET), Moscow;

    Dollezhal Research and Development Institute of Power Engineering (NIKIET), Moscow;

    Dollezhal Research and Development Institute of Power Engineering (NIKIET), Moscow;

    Dollezhal Research and Development Institute of Power Engineering (NIKIET), Moscow;

    Dollezhal Research and Development Institute of Power Engineering (NIKIET), Moscow;

    Dollezhal Research and Development Institute of Power Engineering (NIKIET), Moscow;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:39:16

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号