首页> 外文期刊>Atmospheric environment >Development And Validation Of The Volatile Correction Model For Pm_(10) - An Empirical Method For Adjusting Teom Measurements For Their Loss Of Volatile Particulate Matter
【24h】

Development And Validation Of The Volatile Correction Model For Pm_(10) - An Empirical Method For Adjusting Teom Measurements For Their Loss Of Volatile Particulate Matter

机译:Pm_(10)的挥发性校正模型的开发和验证-一种调整Teom测量值以消除其挥发性颗粒物的经验方法

获取原文
获取原文并翻译 | 示例
           

摘要

EU Directives stipulate that PM_(10) should be measured using the gravimetric reference method as laid out in EN12341 [CEN, 1998. Air Quality - Determination of the PM_(10) Fraction of Suspended Particulate Matter -Reference Method and Field Test Procedure to Demonstrate Reference Equivalence of Measurement Methods. European Committee for Standardisation], or an equivalent method as demonstrated using EC guidance [EC, 2005. Demonstration of Equivalence of Ambient Air Monitoring Methods. European Commission Working Group on Guidance for the Demonstration of Equivalence]. There is however a conflict between the requirement to measure PM_(10) using the gravimetric reference method and the need for rapid public reporting, and many member states, including the UK, rely on non-gravimetric techniques to measure PM_(10). In the UK the majority of PM_(10) measurements are made using the Tapered Element Oscillating Microbalance (TEOM), which does not meet the equivalence criteria [Harrison, D., 2006. UK Equivalence Programme for Monitoring of Particulate Matter. Defra, London]. The implied need to upgrade or replace TEOMs with an equivalent automated measurement technique has significant cost implications. The model described in this paper was based on analysis of daily mean measurements of PM_(10) by the Filter Dynamics Measurement System (FDMS) and the TEOM at UK sites. It uses the FDMS measurement of the volatile component of PM_(10) (referred to here as FDMS purge) to correct for differences in the sensitivity to volatile PM_10 between the TEOM and the EU gravimetric reference method. The model equation for the correction of TEOM PM_(10) measurements is: TEOMvcm = TEOM - 1.87 FDMS purge due to the regional homogeneity of volatile PM, the FDMS purge concentration may be measured at a site distant to the TEOM, allowing the possibility of using a single FDMS instrument to correct PM_10 measurements made by several TEOMs in a defined geographical area. The model was assessed against the criteria for the EC Working Group's Guidance for the Demonstration of Equivalence of Ambient Air Monitoring Methods [EC, 2005. Demonstration of Equivalence of Ambient Air Monitoring Methods. European Commission Working Group on Guidance for the Demonstration of Equivalence]. The model satisfies the equivalence criteria using remote FDMS purge measurements for distances up to 200 km (in 22 out of 23 data sets). These data provide strong evidence that the model is a viable tool for correcting measurements from TEOM instruments on the national and local government networks.
机译:欧盟指令规定,应使用EN12341 [CEN,1998年]中规定的重量参考方法测量PM_(10)。空气质量-悬浮颗粒物PM_(10)分数的确定-参考方法和现场测试程序以证明测量方法的参考当量。欧洲标准化委员会],或使用EC指南证明的等效方法[EC,2005。环境空气监测方法的等效性证明。欧洲委员会关于等值证明的指导工作组]。但是,使用重量参考法测量PM_(10)的需求与快速公开报告的需求之间存在冲突,包括英国在内的许多成员国都依靠非重力技术来测量PM_(10)。在英国,大多数PM_(10)测量是使用不满足等效标准的锥形元素振荡微量天平(TEOM)进行的[Harrison,D.,2006。英国等效物监测计划。 Defra,伦敦]。用等效的自动测量技术升级或替换TEOM的隐含需求具有重大的成本影响。本文描述的模型是基于英国动力学中心的过滤器动态测量系统(FDMS)和TEOM对PM_(10)的日均测量结果进行分析的。它使用PM_(10)中挥发性成分的FDMS测量(在此称为FDMS清除)来校正TEOM和EU重量基准方法之间对挥发性PM_10敏感性的差异。校正TEOM PM_(10)测量值的模型方程式为:TEOMvcm = TEOM-1.87 FDMS吹扫由于挥发性PM的区域均匀性,可以在远离TEOM的位置测量FDMS吹扫浓度,使用一台FDMS仪器来纠正由在定义的地理区域中的几个TEOM进行的PM_10测量。该模型是根据EC工作组的《环境空气监测方法等效性示范指南》 [EC,2005年。示范性的环境空气监测方法等效性指南]的标准进行评估的。欧洲委员会关于等值证明的指导工作组]。该模型使用远程FDMS吹扫测量来满足长达200 km的距离(在23个数据集中的22个中)的等效标准。这些数据提供了有力的证据,表明该模型是从国家和地方政府网络上的TEOM仪器校正测量值的可行工具。

著录项

  • 来源
    《Atmospheric environment》 |2009年第13期|2132-2141|共10页
  • 作者单位

    King's College London, Environmental Research Group, Franklin-Wilkins Building, 150 Stamford Street, London, SE1 9NH, UK;

    King's College London, Environmental Research Group, Franklin-Wilkins Building, 150 Stamford Street, London, SE1 9NH, UK;

    King's College London, Environmental Research Group, Franklin-Wilkins Building, 150 Stamford Street, London, SE1 9NH, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    TEOM; fdms; gravimetric reference method; equivalence; pm_(10);

    机译:TEOM;fdms;重力参考法;等效性;pm_(10);

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号