首页> 外文期刊>Architectural science review >Atrium and its adjoining spaces: a study of the influence of atrium fagade design
【24h】

Atrium and its adjoining spaces: a study of the influence of atrium fagade design

机译:中庭及其毗连空间:中庭立面设计的影响研究

获取原文
获取原文并翻译 | 示例
       

摘要

Atrium buildings have been unsuccessful in utilizing available daylight in spaces adjoining the atria. Several studies indicate the potential to improve daylight in adjoining spaces through glazing distributions of progressive increase in the amount of openings from the upper to the lower floors in medium-scale atria. The aim of this investigation was to study parametrically the effects of glazing variations in the fagade on daylight factors (DFs) in the atrium and its adjoining spaces under overcast sky conditions. Using Ecotect and Radiance, the objective was to provide optimum glazing ratios for a four-sided, top-lit, square atrium building of Wl 0.8. Three glazing compositions were evaluated according to the progressive increase in openings. Each composition, presented as curves, comprises five options worth 20, 30, 40, 50 and 60% openings on the top floor with a progressive increase until 100% opening is reached on the ground floor. The study concluded that fagade compositions have almost no influence on the lower floor adjoining spaces where more daylight is typically required, but can have significant influence on the top two floors. Having very small windows on the top floor (20%) increases DFs in the adjoining spaces; however, this increase is not significant and compromises light levels on the top two floors. In this study, the option of 60% opening on the top floor, 79% opening on the fourth floor, 92% opening on the third floor, 98% opening on the second floor and 100% opening on the ground floor was recommended, as it increased DFs on the top floors without compromising on DFs on the lower floors.
机译:中庭建筑物在与心房相邻的空间中利用可用的日光一直没有成功。多项研究表明,通过在中等规模的心房中,从上层到下层的开口数量逐渐增加的玻璃分布,可以改善相邻空间的日光。这项研究的目的是在阴暗的天空条件下,对立面的玻璃变化对中庭及其相邻空间的日光因子(DF)的影响进行参数研究。使用Ecotect和Radiance的目的是为Wl 0.8的四面,顶灯,方形中庭建筑提供最佳的玻璃比例。根据开口的逐渐增加来评估三种玻璃组合物。每个组成(以曲线形式表示)包括五个选项,分别在顶层具有20%,30%,40%,50%和60%的开口,并逐渐增加直到在底层达到100%的开口。研究得出的结论是,立面组合物对通常需要更多日光的较低楼层相邻空间几乎没有影响,但可能会对顶层两层产生重大影响。顶层设有很小的窗户(占20%)会增加相邻空间中的DF。但是,这种增加并不显着,并且损害了顶层两层的照明水平。在这项研究中,建议选择顶层开放60%,四层开放79%,三层开放92%,二层开放98%和底层开放100%作为选择。它增加了顶层的DF,而不会损害底层的DF。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号