JORDI, a test facility for measurement of contact resistance distribution in full-size conductor terminations

机译:JORDI,一种用于测量全尺寸导体端子中接触电阻分布的测试设备

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A new test facility, dedicated to the measurement of contact resistance distribution in full-size conductor termination, has been designed and manufactured at CRPP Fusion Technology in Villigen, Switzerland. The facility will be used to characterize and qualify the ITER joints (both prototype and industrial). The basic components of the new facility are: a medium size, liquid helium cryostat to host the termination sample, a cryogenic, parallel resistor array for providing balanced current injection in up to 100 channels, a 10 kA DC power supply (100 channels of each 100 A), a pair of conventional current leads rated at 10 kA and a data acquisition system with 200 analogue input channels (100 voltage and 100 current readouts). As opposed to the earlier attempts where the contact resistance was measured under an unbalanced current distribution (only one strand was connected to the current source) in the new facility the contact resistance is measured under imposed balanced current distribution among all current carrying elements and the voltage drops are sensed simultaneously.
机译:位于瑞士维利根(Villigen)的CRPP Fusion Technology已设计和制造了一个专门用于测量全尺寸导体终端中接触电阻分布的新测试设备。该设施将用于表征和鉴定ITER接头(原型和工业接头)。新设施的基本组成部分是:中型液氦低温恒温器,用于容纳终端样品;低温,并联电阻器阵列,可在多达100个通道中提供平衡电流注入; 10 kA直流电源(每个100通道) 100 A),一对额定电流为10 kA的常规电流引线和一个具有200个模拟输入通道(100个电压和100个电流读数)的数据采集系统。与较早的尝试在新设施中在不平衡电流分布下(仅一根导线连接到电流源)测量接触电阻​​的情况相反,在所有载流元件和电压之间施加平衡电流分布的情况下测量接触电阻滴同时感测到。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号