An Improved Fe–Ni Sulfide Fire Assay Method for Determination of Re, Platinum Group Elements, and Os Isotopic Ratios by Inductively Coupled Plasma– and Negative Thermal Ionization–Mass Spectrometry

机译:电感耦合等离子体-负热电离质谱法测定稀土,铂族元素和Os同位素比的改进的Fe-Ni硫化物火分析方法

获取原文
获取原文并翻译 | 示例
           

摘要

An improved Fe–Ni sulfide fire assay method has been developed for determination of Re, the platinum group elements (PGE), and Os isotopic ratios using inductively coupled plasma–mass spectrometry (ICP-MS) and negative thermal ionization–mass spectrometry (NTI-MS). Recovery of Re using the neoclassical NiS fire assay technique is very low, but recoveries of up to 75% can be achieved by using Fe–Ni sulfide as a collector and Na2B4O7 as a flux. Using isotope dilution for determination of Re, a number of standard reference materials were analyzed for PGE and Re, and the results are consistent with their certified values. Multiple analyses of the reference standard GBW 07290 produced precisions ranging from 2.2% for Os to 5.9% for Ir. The detection limits are 2 pg g−1 for Ru, 1.5 pg g−1 for Rh, 25 pg g−1 for Pd, 23 pg g−1 for Re, 0.7 pg g−1 for Os, 1 pg g−1 for Ir, and 6 pg g−1 for Pt. The low procedural blank of Os (1.3 pg g−1) makes the Fe–Ni sulfide fire assay suitable for analysis of Os isotopic compositions. Using NTI-MS, the 187Os/188Os ratios were measured for WPR-1 and they are consistent with literature values.
机译:已经开发出一种改进的Fe–Ni硫化物火分析方法,用于使用电感耦合等离子体质谱(ICP-MS)和负热电离质谱(NTI)测定Re,铂族元素(PGE)和Os同位素比-多发性硬化症)。使用新古典的NiS火焰分析技术对Re的回收率很低,但是使用Fe-Ni硫化物作为捕集剂和Na 2 B 4 可以达到75%的回收率。 sub> O 7 作为助焊剂。使用同位素稀释法测定Re,对许多标准参考物质的PGE和Re进行了分析,结果与标准值相符。对参考标准GBW 07290的多次分析得出的精度范围从Os的2.2%到Ir的5.9%。 Ru的检出限为2 pg g -1 ,Rh的检出限为1.5 pg g -1 ,Pd的检出限为25 pg g -1 ,23 Re的pg g -1 ,Os的0.7 pg g -1 ,Ir的1 pg g -1 和6 pg g −1 表示铂。 Os的程序空白少(1.3 pg g -1 )使Fe-Ni硫化物着火分析适合分析Os同位素组成。使用NTI-MS测量了WPR-1的 187 Os / 188 Os比率,该比率与文献值一致。

著录项

  • 来源
    《Applied Spectroscopy》 |2009年第11期|1232-1237|共6页
  • 作者

  • 作者单位
  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号