首页> 外文期刊>Applied Physics Letters >Detection of narrow lines in the inhomogeneously broadened line of P1 centers in diamond by double modulation EPR spectroscopy
【24h】

Detection of narrow lines in the inhomogeneously broadened line of P1 centers in diamond by double modulation EPR spectroscopy

机译:通过双重调制EPR光谱检测金刚石中的不均匀扩大P1中心线的窄线

获取原文
获取原文并翻译 | 示例
       

摘要

The study of double modulation continuous wave (CW) electron spin resonance (DM-EPR) is reported to detect narrow "spin-packet"-like lines within an inhomogeneous CW-EPR line of low concentration PI (N_s~0) centers ([N_s~0] < 1 ppm) in diamond. These narrow lines appear as peaks at multiples of modulation frequency in the double modulation spectrum. It is shown that the respective line shape can be fitted assuming two Lorentzian line shapes. The linewidth of the narrower Lorentzian is comparable with the linewidth of the Lorentzian obtained from the T_2 relaxation time (δ_1 = 1/πT_2) estimated from the Hahn echo pulsed-EPR experiment. The broader component (δ_2) correlates with the T_2 relaxation time obtained from the free induction decay measurement of the inhomogeneous spectral line shape of the P1 center. The ratio δ_2/δ_1 ~ 18 derived from DM-EPR measurements approaches within the experimental error the value T_2/T_2~* ~ 16 derived from pulsed-EPR. Sensitivity to the small shift of the magnetic field (~0.6μT) was shown to be detectable from the broadening behavior of the δ_2 component. The results promote DM-EPR as a method complementary to pulsed-EPR for studying coherence times of low density paramagnetic centers in a diamond lattice like nitrogen-vacancy (NV~-) center, since it exhibits similar properties to the here investigated P1 center in terms of long relaxation time at a monitored low concentration.
机译:据报道,双调制连续波(CW)电子自旋共振(DM-EPR)的研究检测低浓度PI(N_S〜0)中心的非均匀CW-EPR线内的窄“旋转分组”的线条([ n_s〜0] <1 ppm)在钻石中。这些窄线显示为双调制频谱中调制频率倍数的峰值。结果表明,假设两个Lorentzian线形状可以安装各个线形。较窄的Lorentzian的线宽与从HAHN回波脉冲 - EPR实验估计的T_2弛豫时间(Δ_1= 1 /πt_2)获得的Lorentzian的线宽相当。更宽的组分(Δ_2)与从P1中心的非均匀光谱线形状的自由感应衰减测量获得的T_2弛豫时间相关。从DM-EPR测量结果导出的比率Δ_2/Δ_1〜18在实验误差内的方法T_2 / T_2〜*〜16导出的脉冲 - EPR。显示对磁场的小偏移(〜0.6μt)的敏感性可从Δ_2组分的展大行为中检测到可检测。结果促进DM-EPR作为对脉冲 - EPR互补的方法,用于研究氮空缺(NV〜 - )中心等金刚石晶格中的低密度顺磁中心的相干时间,因为它表现出与这里的类似性质研究的P1中心监测低浓度的长弛豫时间条款。

著录项

  • 来源
    《Applied Physics Letters》 |2020年第15期|153503.1-153503.6|共6页
  • 作者

    B. Rakvin; D. Caric; M. Kveder;

  • 作者单位

    Ruder Boskovic Institute Division of Physical Chemistry Bijenicka 54 Zagreb Croatia;

    Ruder Boskovic Institute Division of Physical Chemistry Bijenicka 54 Zagreb Croatia;

    Ruder Boskovic Institute Division of Physical Chemistry Bijenicka 54 Zagreb Croatia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 22:18:05

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号