Measurement of relative biological effectiveness of protons in human cancer cells using a laser-driven quasimonoenergetic proton beamline

机译:使用激光驱动准单能质子束线测量人癌细胞中质子的相对生物学有效性

获取原文
获取原文并翻译 | 示例
           

摘要

Human cancer cells are irradiated by laser-driven quasimonoenergetic protons. Laser pulse intensities at the 5 X 1019 W/cm2 level provide the source and acceleration field for protons that are subsequently transported by four energy-selective dipole magnets. The transport line delivers 2.25 MeV protons with an energy spread of 0.66 MeV and a bunch duration of 20 ns. The survival fraction of in vitro cells from a human salivary gland tumor is measured with a colony formation assay following proton irradiation at dose levels of up to 8 Gy, for which the single bunch dose rate is 1 × 10~7 Gy/s and the effective dose rate is 0.2 Gy/s for 1 Hz repetition of irradiation. Relative biological effectiveness at the 10% survival fraction is measured to be 1.20 ±0.11 using protons with a linear energy transfer of 17.1 keV/μm.
机译:激光驱动的准单能质子辐照人类癌细胞。 5 X 1019 W / cm2级别的激光脉冲强度为质子提供了源场和加速度场,质子随后由四个能量选择偶极磁体传输。传输线提供2.25 MeV质子,能量散布为0.66 MeV,束流持续时间为20 ns。质子辐照后,在不超过8 Gy的剂量水平下,通过集落形成测定法测量人唾液腺肿瘤体外细胞的存活分数,单束剂量率为1×10〜7 Gy / s, 1 Hz重复照射的有效剂量率为0.2 Gy / s。使用质子的线性能量转移为17.1 keV /μm,质子在10%存活率时的相对生物学有效性为1.20±0.11。

著录项

  • 来源
    《Applied Physics Letters》 |2011年第5期|p.053701.1-053701.3|共3页
  • 作者单位

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan,Hyogo Ion Beam Medical Center (HIBMC), Hyogo 679-5165, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Hyogo Ion Beam Medical Center (HIBMC), Hyogo 679-5165, Japan;

    National Institute of Biomedical Innovation, Osaka 567-0085, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

    Photo-Medical Research Center, JAEA, Kyoto 619-0215, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号