...
首页> 外文期刊>Applied Optics >Two-wave-band color-mixing binoculars for the detection of wholesome and unwholesome chicken carcasses: a simulation
【24h】

Two-wave-band color-mixing binoculars for the detection of wholesome and unwholesome chicken carcasses: a simulation

机译:两波段混色双筒望远镜,用于检测有益和不有益的鸡体:模拟

获取原文
获取原文并翻译 | 示例

摘要

Visual inspection of wholesome and unwholesome chicken carcasses with a novel two-narrowband color-mixing technique for optically enhanced binoculars is simulated. From mean spectra of wholesome, airsacculitis (air-sac), cadaver, inflammatory process (IP), septicemia-toxemia (septox), and tumor chicken samples, 10 nm wave-band pairs are selected using color difference and chromaticness difference indices for simulation of multitarget and single-target detection. The color appearance simulation uses the CIECAM97s color appearance model. Results show that for multitarget detection, the wave-band pair of (454 nm, 578 nm) is able to differentiate all six chicken conditions. For single-target detection of wholesome, air-sac, cadaver, and tumor, the wave-band pairs of (449 nm, 571 nm), (441 nm, 576 nm), (458 nm, 576 nm), and (431 nm, 501 nm), respectively, easily distinguish the target condition from the other five conditions. For single-target detection of IP and septox, the wave-band pairs of (454 nm, 591 nm) and (454 nm, 590 nm), respectively, are able to differentiate the target conditions from wholesome and tumor conditions but have difficulty with the other chicken conditions. The two-color-mixing technique shows promise for use in small-scale processing plant environments to improve the visual inspection process.
机译:模拟了用新颖的两窄带混色技术对光学增强的双筒望远镜进行有益和不有益的鸡尸体的目视检查。从健康,气管炎(气囊),尸体,炎性过程(IP),败血性毒血症(septox)和肿瘤鸡样本的平均光谱中,使用色差和色度差指标选择10 nm波段对进行模拟多目标和单目标检测。颜色外观模拟使用CIECAM97的颜色外观模型。结果表明,对于多目标检测,波长对(454 nm,578 nm)能够区分所有六个鸡条件。对于健康,气囊,尸体和肿瘤的单目标检测,分别为(449 nm,571 nm),(441 nm,576 nm),(458 nm,576 nm)和(431)的波段对,501 nm),可以轻松地将目标条件与其他五个条件区分开。对于IP和隔垫的单目标检测,分别为(454 nm,591 nm)和(454 nm,590 nm)的波段对能够区分目标状况与健康状况和肿瘤状况,但是很难其他鸡肉情况。两种颜色的混合技术显示出有望在小型加工厂环境中使用,以改善外观检查过程。

著录项

  • 来源
    《Applied Optics 》 |2005年第26期| p.5454-5462| 共9页
  • 作者单位

    Instrumentation and Sensing Laboratory, Henry A. Wallace Beltsville Agricultural Research Center, Agricultural Research Service, U.S.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 光学 ;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号