The correct formula of the thermal focal length in a side-pumped Nd:YAG laser rod is discussed and confirmed by experimental results. It is shown that thermally induced stresses that cause a distortion of flatness occur within the region of the whole rod. The presented calculations are in agreement with the experimental observations. The results reveal that the temperature-dependent variation of the refractive index and the distortion caused by the thermally induced stresses constitute the major contributions to thermal lensing.
机译:讨论了侧抽Nd:YAG激光棒中热焦距的正确公式,并通过实验结果加以证实。已经表明,在整个杆的区域内发生引起平面度变形的热应力。提出的计算与实验观察结果一致。结果表明,随温度变化的折射率变化和由热应力引起的变形是热透镜的主要作用。