首页> 外文期刊>Applied Acoustics >Identification of noise sources on a residential split-system air-conditioner using sound intensity measurements
【24h】

Identification of noise sources on a residential split-system air-conditioner using sound intensity measurements

机译:使用声音强度测量识别住宅分体式空调的噪声源

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents the results of experimental studies of the noise of a residential split-system air-conditioner unit. The compressor and condenser and associated fans were removed from the unit and did not form part of the studies. Care was taken with the unit to separate the inlet and exhaust noise from the noise radiated from the cabinet. The measurements were made with a two-microphone sound intensity probe and these resulted in sound power level data. The sound power levels produced by radiation from the inlet, exhaust and cabinet were obtained for five different volume flow rates. The effect on the sound power generated by removing the coil was investigated. Measurements and subjective studies show that the low frequency sound is predominantly radiated from the exhaust and inlet. At high frequency, the cabinet noise dominates.
机译:本文介绍了住宅分体式空调机组噪声的实验研究结果。压缩机和冷凝器以及相关的风扇已从设备中拆除,这并不构成研究的一部分。小心地将设备的进气和排气噪音与机柜发出的噪音分开。用一个两麦克风的声音强度探头进行测量,并得到声功率级数据。对于五个不同的体积流量,获得了由进气口,排气口和机壳辐射产生的声功率级。研究了通过移除线圈对声功率的影响。测量和主观研究表明,低频声音主要从排气口和进气口发出。在高频下,机柜噪声占主导地位。