首页> 外文期刊>Applied Acoustics >Scale model study of balcony insertion losses on a building facade with non-parallel line sources
【24h】

Scale model study of balcony insertion losses on a building facade with non-parallel line sources

机译:非平行线源的建筑立面上阳台插入损耗的比例模型研究

获取原文
获取原文并翻译 | 示例
           

摘要

The screening effect of balconies on a building facade in the case where the noise source is not parallel to the facade is studied using scale model experiment in the present study. Results show that the angle of source inclination to the facade has substantial effects on the balcony insertion loss in the presence of a traffic noise spectrum. Less amount of noise amplification is observed when the source is inclined compared to the case of parallel source in the presence of balcony ceiling reflections. Regression formulae in terms of three independent angles which determine the positions of the balcony and its ceiling relative to the noise source are developed for the prediction of balcony insertion loss. The discrepancy between measurements and predictions is within engineering tolerance.
机译:在本研究中,使用比例模型实验研究了在噪声源与外墙不平行的情况下,阳台对建筑物外墙的屏蔽效果。结果表明,在存在交通噪声频谱的情况下,光源与立面的倾斜角度对阳台的插入损耗有很大影响。与存在阳台天花板反射的平行声源相比,倾斜声源时观察到的噪声放大量较小。建立了三个独立角度的回归公式,用于确定阳台及其天花板相对于噪声源的位置,以预测阳台的插入损耗。测量和预测之间的差异在工程公差范围内。

著录项

  • 来源
    《Applied Acoustics》 |2010年第10期|P.947-954|共8页
  • 作者

    S.K. Tang;

  • 作者单位

    Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    insertion loss; balcony building facade; barrier;

    机译:插入损耗阳台建筑立面;屏障;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号