首页> 外文期刊>Applied Acoustics >Transfer matrix modeling of a recessed microphone for unsteady surface pressure measurements
【24h】

Transfer matrix modeling of a recessed microphone for unsteady surface pressure measurements

机译:用于非稳定表面压力测量的嵌入式麦克风的传递矩阵建模

获取原文
获取原文并翻译 | 示例
       

摘要

Recessed microphones are commonly used for unsteady surface pressure measurements, either due to space limitations or to satisfy performance requirements. A technique is developed using transfer matrices to design a configuration by modeling its frequency response. This.technique is beneficial since it provides guidance to optimize the recessed configuration prior to fabrication. The recessed nature also allows for utilization of closely-spaced pressure ports on a surface, thus providing an inexpensive means for measuring unsteady surface pressures with high spatial resolution. A tube-branch design capable of achieving a 10-kHz bandwidth is presented and validated experimentally using an acoustic plane wave tube. Published by Elsevier Ltd.
机译:由于空间限制或满足性能要求,嵌入式麦克风通常用于不稳定表面压力的测量。开发了一种使用传递矩阵通过对频率响应建模来设计配置的技术。该技术是有益的,因为它提供了在制造之前优化凹陷结构的指导。凹陷的性质还允许利用在表面上的紧密间隔的压力端口,因此提供了一种用于以高空间分辨率测量不稳定的表面压力的廉价装置。提出了一种能够实现10 kHz带宽的电子管分支设计,并使用了声平面波管进行了实验验证。由Elsevier Ltd.发布

著录项

  • 来源
    《Applied Acoustics》 |2017年第ptaa期|185-190|共6页
  • 作者单位

    Univ Florida, Interdisciplinary Microsyst Grp, Gainesville, FL 32611 USA;

    Univ Florida, Interdisciplinary Microsyst Grp, Gainesville, FL 32611 USA|Ford Motor Co, Program NVH, 20800 Oakwood Blvd, Dearborn, MI 48121 USA;

    Florida State Univ, FCAAP, Tallahassee, FL 32310 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Transfer matrices; Recessed microphone; Frequency response; Microphone calibration;

    机译:传输矩阵;嵌入式麦克风;频率响应;麦克风校准;