首页> 外文期刊>The Annals of Occupational Hygiene >MONITORING SURFACE AND AIRBORNE INORGANIC CONTAMINATION IN THE WORKPLACE BY A FIELD PORTABLE X-RAY FLUORESCENCE SPECTROMETER
【24h】

MONITORING SURFACE AND AIRBORNE INORGANIC CONTAMINATION IN THE WORKPLACE BY A FIELD PORTABLE X-RAY FLUORESCENCE SPECTROMETER

机译:用便携式X射线荧光光谱仪监测车间表面和空气中的无机污染。

获取原文
获取原文并翻译 | 示例
       

摘要

Assessment of a field-portable energy dispersive X-ray fluorescence spectrometer (PXRFS) was carried out to determine its performance characteristics for direct analysis of surface deposits and airborne inorganic contamination collected on millipore filters. Lower limits of detection (LLDs) determined for 18 elements were found to be below the required sensitivity of analysis, one-tenth of the occupational exposure limit, with the exception of Pb and Cd. Precision of determinations above the LLD indicated that the standard deviation in analysis was less than 10%. Results of PXRFS analyses of millipore filters used in sampling airborne contamination agree well with results obtained by a laboratory-based XRF method. Results of monitoring Pb, Cd, As, Hg, Fe, Mn and Ni contamination on workplace surfaces show good correlation between direct monitoring and surface wipe sampling. Levels of contaminants on workplace surfaces were found to vary between 0 and 1200 μg cm~(-2) on non-textile surfaces; in office areas up to 1458 μg Cd cm~(-2), 862 μg Pb cm~(-2) and 46 μg Hg cm~(-2) were found on carpets. The findings indicate that the portable XRF monitor can provide rapid on-site analyses of surfaces, filters and powders and thus play a key role in a cost-effective sampling and analysis strategy.
机译:对现场便携式能量色散X射线荧光光谱仪(PXRFS)进行了评估,以确定其性能特征,以直接分析微孔滤池上收集的表面沉积物和空气中的无机污染物。发现对18种元素的检测下限(LLD)低于分析要求的灵敏度,是职业暴露限值的十分之一,但Pb和Cd除外。 LLD之上的测定精度表明,分析中的标准偏差小于10%。用于空气污染物采样的微孔过滤器的PXRFS分析结果与基于实验室的XRF方法获得的结果非常吻合。监测工作场所表面上的Pb,Cd,As,Hg,Fe,Mn和Ni污染的结果表明,直接监测与表面擦拭采样之间具有良好的相关性。在非纺织表面上,工作场所表面的污染物水平在0-1200μgcm〜(-2)之间变化。在办公室区域,地毯上的镉含量高达1458μgCd cm〜(-2),Pb cm〜(-2)862μgHg cm〜(-2)。研究结果表明,便携式XRF监测仪可以提供对表面,过滤器和粉末的快速现场分析,因此在具有成本效益的采样和分析策略中起着关键作用。

著录项

  • 来源
    《The Annals of Occupational Hygiene》 |1996年第5期|p.589-610|共22页
  • 作者

    A. A. Dost;

  • 作者单位

    Health and Safety Laboratory, Health and Safety Executive, Broad Lane, Sheffield S3 7HQ, U.K.;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 劳动卫生;
  • 关键词

  • 入库时间 2022-08-18 00:23:55