首页> 外文期刊>The Annals of Occupational Hygiene >Changes in the Performances of Filter Media During Clogging and Cleaning Cycles
【24h】

Changes in the Performances of Filter Media During Clogging and Cleaning Cycles

机译:堵塞和清洁周期中滤材性能的变化

获取原文
获取原文并翻译 | 示例
       

摘要

The performance of two filter media used in industrial air cleaning were studied both in the initial state (new filter) and after a number of collection and pulse pressure cleaning cycles. The main difference between them is that one has anti-clogging properties and the other does Not. The test aerosol is composed of alumina particles with a median volumetric diameter of 2.6 μm (MMAD=4.8μm) generated at a concentration of 700 mg m~-3. Filtration took place at a velocity of 2 cm s~-1. Two parameters, namely pressure drop and efficiency, were monitored according to the collection and cleaning cycles.
机译:在初始状态(新过滤器)以及经过多次收集和脉冲压力清洗循环后,都研究了用于工业空气净化的两种过滤介质的性能。它们之间的主要区别在于,一个具有防阻塞特性,另一个没有。测试的气雾剂由氧化铝颗粒组成,其中值体积直径为2.6μm(MMAD =4.8μm),浓度为700 mg m〜-3。过滤以2cm s -1的速度进行。根据收集和清洁周期,监测了两个参数,即压降和效率。