This article describes an ion chromatography method to analyze trace concentration of perchlorate in drinking water. Perchlorate was separated from aions commonly found in groundwater and surface water by elution through an AS5 anion exchange column with 120 mmol/L sodium hydroxide +2 mmol/L ρ-cyanophenol. Analyses were measured by conductometric detection using signals enhanced by chemical suppression of the conductance from the eluent. A 740-μL sample injection provided the sample mass necessary to achieve a perchlorate method detection limit of <=1 μg/`L and a working range of 2.5-100 μ g/L`,without sample preconcentration. Interference studies showed that 5.0μg/L of perchlorate could be measured in the presence of 1,000 mg/L of bicarbonate, chloride, or sulfate. The method was successfully used to survey drinking water wells in California considered vulnerable to perchlorate contamination.
机译:本文介绍了一种离子色谱法,用于分析饮用水中的痕量高氯酸盐。通过使用120 mmol / L氢氧化钠+2 mmol / L对氰基苯酚的AS5阴离子交换柱洗脱,将高氯酸盐从地下水和地表水中常见的阴离子中分离出来。通过电导检测来测量分析结果,信号通过化学抑制洗脱液的电导来增强。 740μL样品进样提供了在不进行样品预浓缩的情况下达到<= 1μg/ L的高氯酸盐方法检测极限和2.5-100μg / L`的工作范围所需的样品质量。干扰研究表明,在碳酸氢盐,氯化物或硫酸盐为1000毫克/升的情况下,高氯酸盐的含量为5.0μg/ L。该方法已成功用于调查加利福尼亚州易受高氯酸盐污染的饮用水井。