摘要

In this study, we show that black carbon (BC) mass concentrations measured by different techniques are consistent and traceable. First, we present the volatilities of 13 organic compounds passed through a heated inlet. These data were used to quantify the interference of organic aerosols on the BC measurement techniques. The masses of the refractory particles that incandesce (m*ref) were used to calibrate BC mass measured by a single-particle soot photometer (SP2), which uses laser-induced incandescence. This calibration was influenced little by refractory organics and agreed well with that of fullerene soot, which indicates the consistency of the standards. We estimated the interference of pyrolyzed refractory organics on the BC measured with a filter-based absorption photometer continuous soot monitoring system (COSMOS) with a heated inlet to be small in Asia. This was also confirmed by the stable mass absorption cross section (MAC) obtained by the high correlations between BC mass concentrations measured by COSMOS (M COSMOS) and those measured by the thermal-optical transmittance method (M TOT) (Kondo et al. 200921. Kondo , Y. , Sahu , L. , Kuwata , M. , Miyazaki , Y. , Takegawa , N. , Moteki , N. , Imaru , J. , Han , S. , Nakayama , T. , Hu , M. , Kim , Y. J. and Kita , K. 2009 . Stabilization of the Mass Absorption Cross Section of Black Carbon for Filter-Based Absorption Photometry by the Use of a Heated Inlet . Aerosol Sci. Technol. , 43 : 741 - 756 . View all references). M COSMOS was also compared with total BC mass concentrations measured with an SP2 (M SP2) in Tokyo in 2009. M COSMOS and M SP2 were highly correlated (r 2= 0.97) and agreed to within about 10% on average. These results demonstrate that M SP2, M COSMOS, and M TOT were nearly identical. Use of the masses of incandescing refractory BC particles for calibration of BC mass concentrations determined by different techniques gave consistent results.
机译:在这项研究中,我们显示了通过不同技术测得的黑碳(BC)质量浓度是一致且可追溯的。首先,我们介绍了通过加热的进样口的13种有机化合物的挥发性。这些数据用于量化有机气溶胶对BC测量技术的干扰。将白化的难熔颗粒的质量(m * ref )用于校准由单颗粒烟灰光度计(SP2)测得的BC质量,该单颗粒煤灰光度计使用激光诱导的白炽度。该校准几乎不受耐火有机物的影响,并且与富勒烯烟灰的校准非常吻合,这表明标准的一致性。我们估计,在亚洲,使用带过滤器的吸收式光度计连续烟灰监测系统(COSMOS)加热的入口测量的热解耐火有机物对BC的干扰较小。这也得到了稳定的质量吸收截面(MAC)的证实,该截面是通过COSMOS测量的BC质量浓度(M COSMOS )和通过热光透射法测量的BC质量浓度(M < sub> TOT )(Kondo等,200921。Kondo,Y.,Sahu,L。,桑田,M。,宫崎骏,Y。,竹川N.,Moteki,N.,Imaru,J。, Han,S.,Nakayama,T.,Hu,M.,Kim,YJ和Kita,K. 2009.通过使用加热的进气口稳定用于过滤器吸收光度法的黑炭的质量吸收截面。 Sci。Technol。,43:741-756。查看所有参考文献。还比较了M COSMOS 和2009年在东京用SP2(M SP2 )测量的总BC质量浓度。M COSMOS 和M SP2 高度相关(r 2 = 0.97)并且平均在10%左右。这些结果表明,M SP2 ,M COSMOS 和M TOT 几乎相同。使用难以控制的难治性BC颗粒的质量来校准由不同技术确定的BC质量浓度可得到一致的结果。

著录项

  • 来源
    《Aerosol Science and Technology》 |2011年第2期|p.295-312|共18页
  • 作者单位

    Research Center for Advanced Science and Technology, University of Tokyo, Tokyo, Japan Department of Earth and Planetary Science, Graduate School of Science, University of Tokyo, Tokyo, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:57:39

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号