首页> 外文期刊>Advances in Structural Engineering >Experimental study of light gauge steel framing floor systems under fire conditions
【24h】

Experimental study of light gauge steel framing floor systems under fire conditions

机译:轻型钢框架地板系统在火灾条件下的试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Cold-formed steel members can be assembled in various combinations to provide cost-efficient and safe light gauge floor systems for buildings. Such light gauge steel framing floor systems are widely accepted in industrial and commercial building construction. Light gauge steel framing floor systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Floor assemblies with higher fire resistance rating are needed to develop resilient building systems for extreme fire events. Recently, a new composite panel system based on external insulation has been developed for light gauge steel framing floors to provide higher fire resistance rating under fire conditions. This article presents the details of an experimental investigation of light gauge steel framing floors made of both the conventional (with and without cavity insulation) and the new composite panel systems under standard fires. Analysis of the fire test results showed that the thermal and structural performance of externally insulated light gauge steel framing floor system was superior than conventional light gauge steel framing floors with or without cavity insulation. Details of the experimental results including the temperature and deflection profiles measured during the tests are presented along with the joist failure modes. Such fire performance data can be used in the numerical modelling of light gauge steel framing floor systems to further improve the understanding of their fire behaviour and to develop suitable fire design rules.
机译:冷弯型钢构件可以以各种组合方式进行组装,从而为建筑物提供经济高效且安全的轻型地板系统。这种轻型钢框架地板系统在工业和商业建筑中被广泛接受。轻型钢框架地板系统必须设计成可作为防火区的边界并提供足够的防火性。需要具有较高耐火等级的地板组件来开发用于极端火灾的弹性建筑系统。最近,已经开发出一种基于外部绝缘的新型复合板系统,用于轻型钢框架地板,以在火灾条件下提供更高的耐火等级。本文详细介绍了在常规火灾下对由常规(带和不带腔绝缘)和新型复合板系统制成的轻型钢框架地板进行的实验研究的细节。耐火测试结果分析表明,外部隔热轻型钢框架地板系统的热性能和结构性能优于具有或不具有空腔隔热层的常规轻型钢框架地板。给出了实验结果的详细信息,包括在测试过程中测得的温度和挠度曲线以及托梁破坏模式。这样的防火性能数据可用于轻型钢框架地板系统的数值建模,以进一步提高对它们的防火性能的了解并制定合适的防火设计规则。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号