首页> 外文期刊>Advances in Engineering Software >The influence of electrode position and output current on the corrosion related electro-magnetic field of ship
【24h】

The influence of electrode position and output current on the corrosion related electro-magnetic field of ship

机译:电极位置和输出电流对船舶腐蚀相关电磁场的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The magnitude of ship's corrosion related electro-magnetic field was significantly influenced by the electrode positions and output current of the impressed current cathodic protection (ICCP) system. In order to minimize corrosion related electro-magnetic field, we must know how the electrode position and output current influence the strength of corrosion related electro-magnetic field. In this paper, the corrosion related electro-magnetic field was simulated by boundary element method (BEASY software) with different electrode position and output current, and then the influence of electrode position and output current on corrosion related electro-magnetic field was analyzed, last the optimized electrode position was ascertained.
机译:船舶腐蚀相关电磁场的大小受外加电流阴极保护(ICCP)系统的电极位置和输出电流的影响很大。为了最小化与腐蚀有关的电磁场,我们必须知道电极位置和输出电流如何影响与腐蚀有关的电磁场的强度。本文采用边界元法(BEASY软件)对不同电极位置和输出电流的腐蚀相关电磁场进行了模拟,然后分析了电极位置和输出电流对腐蚀相关电磁场的影响,最后确定最佳的电极位置。