The present paper describes the main features of the finite element code NOSA-ITACA for the static and dynamic analysis of masonry buildings of historical interest. The code, which models masonry as a nonlinear elastic material with zero tensile strength and bounded compressive strength, is aimed at assessing the static safety and seismic vulnerability of masonry constructions in light of Italian regulations, as well as modelling possible strengthening interventions. The NOSA-ITACA code has been used to study the "Voltone", a large vaulted masonry structure located beneath the "Piazza della Repubblica" square in Livorno. The structure has been analysed in the presence of permanent and accidental loads, calculated on the basis of current Italian regulations. This case study has provided the opportunity to validate the NOSA-ITACA code and highlighted the key role played by numerical tools in assessing the safety of ancient masonry constructions.
机译:本文介绍了有限元代码NOSA-ITACA的主要特征,用于对具有历史意义的砖石建筑进行静态和动态分析。该规范将砌体建模为具有零拉伸强度和有限抗压强度的非线性弹性材料,旨在根据意大利法规评估砌体结构的静态安全性和地震脆弱性,并对可能的加固措施进行建模。 NOSA-ITACA代码已被用于研究“ Voltone”,这是位于里窝那“ Piazza della Repubblica”广场下方的大型拱形砖石结构。根据意大利现行法规对结构进行了永久性和偶然性载荷分析。该案例研究提供了验证NOSA-ITACA代码的机会,并强调了数字工具在评估古代砖石建筑安全性中的关键作用。