摘要

Point-of-care testing (POCT) is becoming an important adjunct to haematology laboratory practice. An important component of the blood count is the total white cell count (WBC). Previously, this required laborious microscopic cell counting, but it can now be performed by means of automation; however, in many under-resourced countries, costly automated counters are only available in very few central hospitals. Moreover, neither method is practical in most POCT situations. The HemoCue WBC has been developed as a simplified alternative method, consisting of a reagent pre-loaded disposable cuvette together with basic image analysis technology. This report describes an assessment of its utility. The WBC of 500 routine blood samples from the hospital were tested in parallel by the HemoCue WBC and by a reference analyser to assess accuracy and utility of the former. The tests included precision, linearity, type of blood sample and anticoagulant and potential interfering substances in blood specimens. In the tests for accuracy, 192 of the 200 showed percentage difference from the NEQAS reference of <10% whilst the remaining eight samples differed by <12%, thus meeting the requirements of Clinical laboratory improvement amendments (CLIA)-88 regulations. Of the samples tested with potential interfering substances only those with >2% normoblasts or reticulocytosis showed significant differences from the reference measurements. The HemoCue WBC is reliable for WBC counts within the analytical range of 0.4–30.0 × 109/l, except in samples where there are significant numbers of normoblasts or reticulocytes. It is simple to use and provides a valuable advance in the facilities available for POCT in haematology.
机译:即时检验(POCT)成为血液学实验室实践的重要辅助手段。血球计数的重要组成部分是白细胞总数(WBC)。以前,这需要费力的微观细胞计数,但是现在可以通过自动化来执行;但是,在许多资源不足的国家/地区,只有很少的中央医院提供昂贵的自动柜员机。而且,这两种方法都不适用于大多数POCT情况。 HemoCue WBC是作为一种简化的替代方法而开发的,它由试剂预装的一次性比色皿和基本的图像分析技术组成。该报告描述了其效用的评估。通过HemoCue WBC和参考分析仪对来自医院的500份常规血液样本的WBC进行了平行测试,以评估前者的准确性和实用性。测试包括精密度,线性,血样类型和抗凝剂以及血样中潜在的干扰物质。在准确性测试中,200个样本中有192个样本显示与NEQAS参考文献的百分比差异小于10%,而其余八个样本的差异小于12%,从而符合临床实验室改进修正案(CLIA)-88的要求。在用潜在的干扰物质测试的样品中,只有> 2%的成正常细胞或网状细胞增多症的样品与参考测量值显示出显着差异。 HemoCue WBC对于在0.4–30.0×10 9 / l的分析范围内的WBC计数是可靠的,除了在有大量成胚细胞或网织红细胞的样品中。它使用简单,在血液学中可用于POCT的设施方面提供了宝贵的进步。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号