The novel automatic flow system, direct-injection detector (DID) integrated with multi-pumping flow system (MPFS), dedicated for the photometric determination of orthophosphates in wastewater and freshwater samples is for the first time described. All reagents and the sample were injected simultaneously, in counter-current into the reaction-detection chamber by the system of specially selected for this purpose solenoid micro-pumps. The micro-pumps provided good precision and accuracy of the injected volumes. For the determination of orthophosphates, the molybdenum blue method was employed. The developed method can be used to detect orthophosphate in the range 0.1–12 mg L−1, with the repeatability (RSD) about 2.2% at 4 mg L−1 and a very high injection throughput of 120 injections h−1. It was possible to achieve a very small consumption of reagents (10 μL of ammonium molybdate and 10 μL of ascorbic acid) and sample (20 μL). The volume of generated waste was only 440 μL per analysis. The method has been successfully applied, giving a good accuracy, to determination of orthophosphates in complex matrix samples: treated wastewater, lake water and reference sample of groundwater. The developed system is compact, small in both size and weight, requires 12 V in supply voltage, which are desirable for truly portable equipment used in routine analysis. The simplicity of the system should result in its greater long-time reliability comparing to other flow methods previously described.
机译:首次介绍了新颖的自动流量系统,与多泵流量系统(MPFS)集成的直接进样检测器(DID),专用于光度测定废水和淡水样品中的正磷酸盐。通过专门为此选择的螺线管微型泵系统,将所有试剂和样品同时逆流同时注入反应检测室。微型泵提供了良好的注入量精度和准确性。为了测定正磷酸盐,采用了钼蓝法。所开发的方法可用于检测范围为0.1–12 mg L -1 的正磷酸盐,在4 mg L -1 时的重复性(RSD)约为2.2% 120次注射的非常高的注射通量h -1 。可以实现非常少量的试剂(10μL钼酸铵和10μL抗坏血酸)和样品(20μL)消耗。每次分析产生的废物量仅为440μL。该方法已成功应用,并以良好的准确度测定了复杂基质样品中的正磷酸盐:处理后的废水,湖水和地下水参考样品。开发的系统紧凑,体积小,重量轻,需要12V的电源电压,这对于常规分析中使用的真正便携式设备是理想的。与先前描述的其他流动方法相比,系统的简单性应导致其更大的长期可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号