首页> 美国卫生研究院文献>Journal of Biomedical Physics Engineering >Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
【2h】

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

机译:使用自适应减法技术从表面肌电信号中去除ECG伪像

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful. Objective: Removing electrocardiogram contamination from electromyogram signals. Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and electrocardiogram signal were recorded from leg muscles, the pectoralis major muscle of the left side and V4, respectively. After the pre-processing, contaminated electromyogram signal is simulated with a combination of clean electromyogram and electrocardiogram artifact. Then, contaminated electromyogram is cleaned using adaptive subtraction method. This method contains some steps; (1) QRS detection, (2) formation of electrocardiogram template by averaging the electrocardiogram complexes, (3) using low pass filter to remove undesirable artifacts, (4) subtraction. Results: Performance of our method is evaluated using qualitative criteria, power spectrum density and coherence and quantitative criteria signal to noise ratio, relative error and cross correlation. The result of signal to noise ratio, relative error and cross correlation is equal to 10.493, 0.04 and %97 respectively. Finally, there is a comparison between proposed method and some existing methods. Conclusion: The result indicates that adaptive subtraction method is somewhat effective to remove electrocardiogram artifact from contaminated electromyogram signal and has an acceptable result.
机译:背景:当从上躯干肌肉记录肌电图信号时,心电图伪影是肌电图信号中的主要污染,因为污染的肌电图无用。 目标 :从肌电图信号中清除心电图污染。 方法:本文分别从腿部肌肉,左侧胸大肌和V4记录清洁的肌电图信号,心电图伪影和心电图信号。预处理后,将干净的肌电图和心电图伪影结合起来模拟受污染的肌电图信号。然后,使用自适应减法清洁受污染的肌电图。此方法包含一些步骤。 (1)QRS检测;(2)通过对心电图复合体求平均来形成心电图模板;(3)使用低通滤波器去除不想要的伪影;(4)减法。 结果:我们使用定性标准,功率谱密度和相干性以及定量标准信噪比,相对误差和互相关性来评估我们方法的性能。信噪比,相对误差和互相关的结果分别等于10.493、0.04和%97。最后,在提议的方法和一些现有方法之间进行了比较。 结论:结果表明,自适应减法可以有效地从污染的肌电信号中去除心电图伪影,并且结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号