您现在的位置:首页>美国卫生研究院文献>Journal of Biomechanical Engineering

期刊信息

  • 期刊名称:

    -

  • 刊频: Bimonthly, 1998-
  • NLM标题: J Biomech Eng
  • iso缩写: -
  • ISSN: -
  • 排序:
  • 显示:
  • 每页:
全选(0
<1/20>
571条结果
  • 机译 经导管主动脉瓣展开进入患者特定主动脉根后瓣周漏的数值参数研究
    摘要:Paravalvular leak (PVL) is a relatively frequent complication after transcatheter aortic valve replacement (TAVR) with increased mortality. Currently, there is no effective method to pre-operatively predict and prevent PVL. In this study, we developed a computational model to predict the severity of PVL after TAVR. Nonlinear finite element (FE) method was used to simulate a self-expandable CoreValve deployment into a patient-specific aortic root, specified with human material properties of aortic tissues. Subsequently, computational fluid dynamics (CFD) simulations were performed using the post-TAVR geometries from the FE simulation, and a parametric investigation of the impact of the transcatheter aortic valve (TAV) skirt shape, TAV orientation, and deployment height on PVL was conducted. The predicted PVL was in good agreement with the echocardiography data. Due to the scallop shape of CoreValve skirt, the difference of PVL due to TAV orientation can be as large as 40%. Although the stent thickness is small compared to the aortic annulus size, we found that inappropriate modeling of it can lead to an underestimation of PVL up to 10 ml/beat. Moreover, the deployment height could significantly alter the extent and the distribution of regurgitant jets, which results in a change of leaking volume up to 70%. Further investigation in a large cohort of patients is warranted to verify the accuracy of our model. This study demonstrated that a rigorously developed patient-specific computational model can provide useful insights into underlying mechanisms causing PVL and potentially assist in pre-operative planning for TAVR to minimize PVL.
  • 机译 聚富马酸丙二醇酯-羟基磷灰石纳米复合材料可作为宫颈笼的合适候选材料
    摘要:A wide range of materials have been used for the development of intervertebral cages. Poly(propylene fumarate) (PPF) has been shown to be an excellent biomaterial with characteristics similar to trabecular bone. Hydroxyapatite (HA) has been shown to enhance biocompatibility and mechanical properties of PPF. The purpose of this study was to characterize the effect of PPF augmented with HA (PPF:HA) and evaluate the feasibility of this material for the development of cervical cages. PPF was synthesized and combined with HA at PPF:HA wt:wt ratios of 100:0, 80:20, 70:30, and 60:40. Molds were fabricated for testing PPF:HA bulk materials in compression, bending, tension, and hardness according to ASTM standards, and also for cage preparation. The cages were fabricated with and without holes and with porosity created by salt leaching. The samples as well as the cages were mechanically tested using a materials testing frame. All elastic moduli as well as the hardness increased significantly by adding HA to PPF (p < 0.0001). The 20 wt % HA increased the moduli significantly compared to pure PPF (p < 0.0001). Compressive stiffness of all cages also increased with the addition of HA. HA increased the failure load of the porous cages significantly (p = 0.0018) compared with nonporous cages. PPF:HA wt:wt ratio of 80:20 proved to be significantly stiffer and stronger than pure PPF. The current results suggest that this polymeric composite can be a suitable candidate material for intervertebral body cages.
  • 机译 在一级研究型大学为非裔美国高中生实施生物医学工程研究经验
    摘要:Enriching science experiences and competencies for underrepresented students during high school years is crucial to increasing their entry into the science pipeline and to improving their preparedness for success in college and STEM careers. The purpose of this paper is to describe the implementation of project ENGAGES, a high school STEM year-long research program for African–American students, mentored by graduate students and postdoctoral researchers at Georgia Tech. It aims to provide an authentic research experience and expose student to the possibility and benefits of attaining an advanced degree and careers in STEM fields. Initial program outcomes include student reported satisfaction with research experience, improved technical skill development, and increased curiosity and interest in STEM careers. Additionally, students indicated increases in college readiness, research skill development, and exposure to STEM careers as a result of interactions with faculty advisors and graduate student mentors, along with laboratory assignments. Lessons learned and potential pitfalls and barriers to acceptance are also discussed.
  • 机译 戊糖基葡萄糖对大鼠腹主动脉瘤壁力学和炎症活性的影响
    摘要:An abdominal aortic aneurysm (AAA) is a permanent localized expansion of the abdominal aorta with mortality rate of up to 90% after rupture. AAA growth is a process of vascular degeneration accompanied by a reduction in wall strength and an increase in inflammatory activity. It is unclear whether this process can be intervened to attenuate AAA growth, and hence, it is of great clinical interest to develop a technique that can stabilize the AAA. The objective of this work is to develop a protocol for future studies to evaluate the effects of drug-based therapies on the mechanics and inflammation in rodent models of AAA. The scope of the study is limited to the use of pentagalloyl glucose (PGG) for aneurysm treatment in the calcium chloride rat AAA model. Peak wall stress (PWS) and matrix metalloproteinase (MMP) activity, which are the biomechanical and biological markers of AAA growth and rupture, were evaluated over 4 weeks in untreated and treated (with PGG) groups. The AAA specimens were mechanically characterized by planar biaxial tensile testing and the data fitted to a five-parameter nonlinear, hyperelastic, anisotropic Holzapfel–Gasser–Ogden (HGO) material model, which was used to perform finite element analysis (FEA) to evaluate PWS. Our results demonstrated that there was a reduction in PWS between pre- and post-AAA induction FEA models in the treatment group compared to the untreated group using either animal-specific or average material properties. However, this reduction was not statistically significant. Conversely, there was a statistically significant reduction in MMP-activated fluorescent signal between pre- and post-AAA induction models in the treated group compared to the untreated group. Therefore, the primary contribution of this work is the quantification of the stabilizing effects of PGG using biomechanical and biological markers of AAA, thus indicating that PGG could be part of a new clinical treatment strategy that will require further investigation.
  • 机译 通过在适应性,经验性和跨学科学习环境中的连续性来改善生物医学工程教育
    摘要:This study reports our experience of developing a series of biomedical engineering (BME) courses having active and experiential learning components in an interdisciplinary learning environment. In the first course, BME465: biomechanics, students were immersed in a simulation laboratory setting involving mannequins that are currently used for teaching in the School of Nursing. Each team identified possible technological challenges directly related to the biomechanics of the mannequin and presented an improvement overcoming the challenge. This approach of exposing engineering students to a problem in a clinical learning environment enhanced the adaptive and experiential learning capabilities of the course. In the following semester, through BME448: medical devices, engineering students were partnered with nursing students and exposed to simulation scenarios and real-world clinical settings. They were required to identify three unmet needs in the real-world clinical settings and propose a viable engineering solution. This approach helped BME students to understand and employ real-world applications of engineering principles in problem solving while being exposed to an interdisciplinary collaborative environment. A final step was for engineering students to execute their proposed solution from either BME465 or BME448 courses by undertaking it as their capstone senior design project (ENGR401-402). Overall, the inclusion of clinical immersions in interdisciplinary teams in a series of courses not only allowed the integration of active and experiential learning in continuity but also offered engineers more practice of their profession, adaptive expertise, and an understanding of roles and expertise of other professionals involved in enhancement of healthcare and patient safety.
  • 机译 验证心血管支架疲劳安全系数计算方法
    摘要:Evaluating risk of fatigue fractures in cardiovascular implants via nonclinical testing is essential to provide an indication of their durability. This is generally accomplished by experimental accelerated durability testing and often complemented with computational simulations to calculate fatigue safety factors (FSFs). While many methods exist to calculate FSFs, none have been validated against experimental data. The current study presents three methods for calculating FSFs and compares them to experimental fracture outcomes under axial fatigue loading, using cobalt-chromium test specimens designed to represent cardiovascular stents. FSFs were generated by calculating mean and alternating stresses using a simple scalar method, a tensor method which determines principal values based on averages and differences of the stress tensors, and a modified tensor method which accounts for stress rotations. The results indicate that the tensor method and the modified tensor method consistently predicted fracture or survival to 107 cycles for specimens subjected to experimental axial fatigue. In contrast, for one axial deformation condition, the scalar method incorrectly predicted survival even though fractures were observed in experiments. These results demonstrate limitations of the scalar method and potential inaccuracies. A separate computational analysis of torsional fatigue was also completed to illustrate differences between the tensor method and the modified tensor method. Because of its ability to account for changes in principal directions across the fatigue cycle, the modified tensor method offers a general computational method that can be applied for improved predictions for fatigue safety regardless of loading conditions.
  • 机译 在低于疼痛阈值的应变处反复进行高速率小平面包膜拉伸,导致大鼠疼痛和脊柱发炎,韧带强度降低
    摘要:Repeated loading of ligamentous tissues during repetitive occupational and physical tasks even within physiological ranges of motion has been implicated in the development of pain and joint instability. The pathophysiological mechanisms of pain after repetitive joint loading are not understood. Within the cervical spine, excessive stretch of the facet joint and its capsular ligament has been implicated in the development of pain. Although a single facet joint distraction (FJD) at magnitudes simulating physiologic strains is insufficient to induce pain, it is unknown whether repeated stretching of the facet joint and ligament may produce pain. This study evaluated if repeated loading of the facet at physiologic nonpainful strains alters the capsular ligament's mechanical response and induces pain. Male rats underwent either two subthreshold facet joint distractions (STFJDs) or sham surgeries each separated by 2 days. Pain was measured before the procedure and for 7 days; capsular mechanics were measured during each distraction and under tension at tissue failure. Spinal glial activation was also assessed to probe potential pathophysiologic mechanisms responsible for pain. Capsular displacement significantly increased (p = 0.019) and capsular stiffness decreased (p = 0.008) during the second distraction compared to the first. Pain was also induced after the second distraction and was sustained at day 7 (p < 0.048). Repeated loading weakened the capsular ligament with lower vertebral displacement (p = 0.041) and peak force (p = 0.014) at tissue rupture. Spinal glial activation was also induced after repeated loading. Together, these mechanical, physiological, and neurological findings demonstrate that repeated loading of the facet joint even within physiologic ranges of motion can be sufficient to induce pain, spinal inflammation, and alter capsular mechanics similar to a more injurious loading exposure.
  • 机译 青光眼大鼠视神经头生物力学个体特定模型的方法学
    摘要:Glaucoma is the leading cause of irreversible blindness and involves the death of retinal ganglion cells (RGCs). Although biomechanics likely contributes to axonal injury within the optic nerve head (ONH), leading to RGC death, the pathways by which this occurs are not well understood. While rat models of glaucoma are well-suited for mechanistic studies, the anatomy of the rat ONH is different from the human, and the resulting differences in biomechanics have not been characterized. The aim of this study is to describe a methodology for building individual-specific finite element (FE) models of rat ONHs. This method was used to build three rat ONH FE models and compute the biomechanical environment within these ONHs. Initial results show that rat ONH strains are larger and more asymmetric than those seen in human ONH modeling studies. This method provides a framework for building additional models of normotensive and glaucomatous rat ONHs. Comparing model strain patterns with patterns of cellular response seen in studies using rat glaucoma models will help us to learn more about the link between biomechanics and glaucomatous cell death, which in turn may drive the development of novel therapies for glaucoma.
  • 机译 肌电图驱动的前向动力学仿真,以估计正常,平滑和弹性步态期间的体内关节接触力
    摘要:Computational models that predict in vivo joint loading and muscle forces can potentially enhance and augment our knowledge of both typical and pathological gaits. To adopt such models into clinical applications, studies validating modeling predictions are essential. This study created a full-body musculoskeletal model using data from the “Sixth Grand Challenge Competition to Predict in vivo Knee Loads.” This model incorporates subject-specific geometries of the right leg in order to concurrently predict knee contact forces, ligament forces, muscle forces, and ground contact forces. The objectives of this paper are twofold: (1) to describe an electromyography (EMG)-driven modeling methodology to predict knee contact forces and (2) to validate model predictions by evaluating the model predictions against known values for a patient with an instrumented total knee replacement (TKR) for three distinctly different gait styles (normal, smooth, and bouncy gaits). The model integrates a subject-specific knee model onto a previously validated generic full-body musculoskeletal model. The combined model included six degrees-of-freedom (6DOF) patellofemoral and tibiofemoral joints, ligament forces, and deformable contact forces with viscous damping. The foot/shoe/floor interactions were modeled by incorporating shoe geometries to the feet. Contact between shoe segments and the floor surface was used to constrain the shoe segments. A novel EMG-driven feedforward with feedback trim motor control strategy was used to concurrently estimate muscle forces and knee contact forces from standard motion capture data collected on the individual subject. The predicted medial, lateral, and total tibiofemoral forces represented the overall measured magnitude and temporal patterns with good root-mean-squared errors (RMSEs) and Pearson's correlation (p2). The model accuracy was high: medial, lateral, and total tibiofemoral contact force RMSEs = 0.15, 0.14, 0.21 body weight (BW), and (0.92 < p2 < 0.96) for normal gait; RMSEs = 0.18 BW, 0.21 BW, 0.29 BW, and (0.81 < p2 < 0.93) for smooth gait; and RMSEs = 0.21 BW, 0.22 BW, 0.33 BW, and (0.86 < p2 < 0.95) for bouncy gait, respectively. Overall, the model captured the general shape, magnitude, and temporal patterns of the contact force profiles accurately. Potential applications of this proposed model include predictive biomechanics simulations, design of TKR components, soft tissue balancing, and surgical simulation.
  • 机译 生长猪颞下颌关节的特性
    摘要:A subset of temporomandibular joint (TMJ) disorders is attributed to joint degeneration. The pig has been considered the preferred in vivo model for the evaluation of potential therapies for TMJ disorders, and practical considerations such as cost and husbandry issues have favored the use of young, skeletally immature animals. However, the effect of growth on the biochemical and biomechanical properties of the TMJ disk and articulating cartilage has not been examined. The present study investigates the effect of age on the biochemical and biomechanical properties of healthy porcine TMJs at 3, 6, and 9 months of age. DNA, hydroxyproline, and glycosaminoglycan (GAG) content were determined and the disks and condyles were tested in uniaxial unconfined stress relaxation compression from 10% to 30% strain. TMJ disks were further assessed with a tensile test to failure technique, which included the ability to test multiple samples from the same region of an individual disk to minimize the intraspecimen variation. No differences in biochemical properties for the disk or compressive properties at 30% stress relaxation in the disk and condylar cartilage were found. In tension, no differences were observed for peak stress and tensile modulus. The collagen content of the condyle was higher at 9 months than 3 months (p < 0.05), and the GAG content was higher at 9 months than 6 months (p < 0.05). There was a trend of increased compressive instantaneous modulus with age. As such, age-matched controls for growing pigs are probably appropriate for most parameters measured.
  • 机译 具有完全面内变形控制的新型小试样平面双轴测试系统
    摘要:Simulations of soft tissues require accurate and robust constitutive models, whose form is derived from carefully designed experimental studies. For such investigations of membranes or thin specimens, planar biaxial systems have been used extensively. Yet, all such systems remain limited in their ability to: (1) fully prescribe in-plane deformation gradient tensor F2D, (2) ensure homogeneity of the applied deformation, and (3) be able to accommodate sufficiently small specimens to ensure a reasonable degree of material homogeneity. To address these issues, we have developed a novel planar biaxial testing device that overcomes these difficulties and is capable of full control of the in-plane deformation gradient tensor F2D and of testing specimens as small as ∼4 mm × ∼4 mm. Individual actuation of the specimen attachment points, combined with a robust real-time feedback control, enabled the device to enforce any arbitrary F2D with a high degree of accuracy and homogeneity. Results from extensive device validation trials and example tissues illustrated the ability of the device to perform as designed and gather data needed for developing and validating constitutive models. Examples included the murine aortic tissues, allowing for investigators to take advantage of the genetic manipulation of murine disease models. These capabilities highlight the potential of the device to serve as a platform for informing and verifying the results of inverse models and for conducting robust, controlled investigation into the biomechanics of very local behaviors of soft tissues and membrane biomaterials.
  • 机译 失水时动脉弹性蛋白的力学性能
    摘要:Elastin is a peculiar elastomer in that it requires water to maintain resilience, and its mechanical properties are closely associated with the immediate aqueous environment. The bulk, extra- and intrafibrillar water plays important roles in both elastic and viscoelastic properties of elastin. In this study, a two-stage liquid–vapor method was developed to investigate the effects of water loss on the mechanical properties of porcine aortic elastin. The tissue samples started in a phosphate-buffered saline (PBS) solution at their fully hydrated condition, with a gravimetric water content of 370±36%. The hydration level was reduced by enclosing the tissue in dialysis tubing and submerging it in polyethylene glycol (PEG) solution at concentrations of 10%, 20%, 30%, and 45% w/v, which reduced the water content of the samples to 258±34%, 224±20%, 109±9%, and 58±3%, respectively. The samples were then transferred to a humidity chamber to maintain the hydration level while the samples underwent equi-biaxial tensile and stress relaxation tests. The concentration of 10% PEG treatment induced insignificant changes in tissue dimensions and stiffness, indicating that the removal of bulk water has less effect on elastin. Significant increases in tangent modulus were observed after 20% and 30% PEG treatment due to the decreased presence of extrafibrillar water. Elastin treated with 45% PEG shows a very rigid behavior as most of the extrafibrillar water is eliminated. These results suggest that extrafibrillar water is crucial for elastin to maintain its elastic behavior. It was also observed that the anisotropy of elastin tends to decrease with water loss. An increase in stress relaxation was observed for elastin treated with 30% PEG, indicating a more viscous behavior of elastin when the amount of extrafibrillar water is significantly reduced. Results from this study shed light on the close association between the bulk, extra- and intrafibrillar water pools and the mechanics of elastin.
  • 机译 结合IVUS和光学相干断层扫描技术以更准确地测量冠状动脉冠层厚度并进行应力/应变计算:一种针对患者的三维流体结构相互作用建模方法
    摘要:Accurate cap thickness and stress/strain quantifications are of fundamental importance for vulnerable plaque research. Virtual histology intravascular ultrasound (VH-IVUS) sets cap thickness to zero when cap is under resolution limit and IVUS does not see it. An innovative modeling approach combining IVUS and optical coherence tomography (OCT) is introduced for cap thickness quantification and more accurate cap stress/strain calculations. In vivo IVUS and OCT coronary plaque data were acquired with informed consent obtained. IVUS and OCT images were merged to form the IVUS + OCT data set, with biplane angiography providing three-dimensional (3D) vessel curvature. For components where VH-IVUS set zero cap thickness (i.e., no cap), a cap was added with minimum cap thickness set as 50 and 180 μm to generate IVUS50 and IVUS180 data sets for model construction, respectively. 3D fluid–structure interaction (FSI) models based on IVUS + OCT, IVUS50, and IVUS180 data sets were constructed to investigate cap thickness impact on stress/strain calculations. Compared to IVUS + OCT, IVUS50 underestimated mean cap thickness (27 slices) by 34.5%, overestimated mean cap stress by 45.8%, (96.4 versus 66.1 kPa). IVUS50 maximum cap stress was 59.2% higher than that from IVUS + OCT model (564.2 versus 354.5 kPa). Differences between IVUS and IVUS + OCT models for cap strain and flow shear stress (FSS) were modest (cap strain <12%; FSS <6%). IVUS + OCT data and models could provide more accurate cap thickness and stress/strain calculations which will serve as basis for further plaque investigations.
  • 机译 利用地面反作用力波形分析牛皮质骨的机械疲劳
    摘要:Stress fractures are a common overuse injury among runners associated with the mechanical fatigue of bone. Several in vivo biomechanical studies have investigated specific characteristics of the vertical ground reaction force (vGRF) in heel-toe running and have observed an association between increased loading rate during impact and individuals with a history of stress fracture. The purpose of this study was to examine the fatigue behavior of cortical bone using vGRF-like loading profiles, including those that had been decomposed into their respective impact and active phase components. Thirty-eight cylindrical cortical bone samples were extracted from bovine tibiae and femora. Hydrated samples were fatigue tested at room temperature in zero compression under load control using either a raw (n = 10), active (n = 10), low impact (n = 10), or high impact (n = 8) vGRF profile. The number of cycles to failure was quantified and the test was terminated if the sample survived 105 cycles. Fatigue life was significantly greater for both impact groups compared to the active (p < 0.001) and raw (p < 0.001) groups, with all low impact samples and 6 of 8 high impact samples surviving 105 cycles. The mean (± SD) number of cycles to failure for the active and raw groups was 12,133±11,704 and 16,552±29,612, respectively. The results suggest that loading rates associated with the impact phase of a typical vGRF in running have little influence on the mechanical fatigue behavior of bone relative to loading magnitude, warranting further investigation of the mechanism by which increased loading rates are associated with stress fracture.
  • 机译 FEBio中计算流体动力学的有限元框架
    摘要:The mechanics of biological fluids is an important topic in biomechanics, often requiring the use of computational tools to analyze problems with realistic geometries and material properties. This study describes the formulation and implementation of a finite element framework for computational fluid dynamics (CFD) in FEBio, a free software designed to meet the computational needs of the biomechanics and biophysics communities. This formulation models nearly incompressible flow with a compressible isothermal formulation that uses a physically realistic value for the fluid bulk modulus. It employs fluid velocity and dilatation as essential variables: The virtual work integral enforces the balance of linear momentum and the kinematic constraint between fluid velocity and dilatation, while fluid density varies with dilatation as prescribed by the axiom of mass balance. Using this approach, equal-order interpolations may be used for both essential variables over each element, contrary to traditional mixed formulations that must explicitly satisfy the inf-sup condition. The formulation accommodates Newtonian and non-Newtonian viscous responses as well as inviscid fluids. The efficiency of numerical solutions is enhanced using Broyden's quasi-Newton method. The results of finite element simulations were verified using well-documented benchmark problems as well as comparisons with other free and commercial codes. These analyses demonstrated that the novel formulation introduced in FEBio could successfully reproduce the results of other codes. The analogy between this CFD formulation and standard finite element formulations for solid mechanics makes it suitable for future extension to fluid–structure interactions (FSIs).
  • 机译 DNA的统计段长度:在高分子物理和下一代基因组学中进行生物力学建模的机会
    • 作者:Kevin D. Dorfman
    • 刊名:Journal of Biomechanical Engineering
    • 2018年第2期
    摘要:The development of bright bisintercalating dyes for deoxyribonucleic acid (DNA) in the 1990s, most notably YOYO-1, revolutionized the field of polymer physics in the ensuing years. These dyes, in conjunction with modern molecular biology techniques, permit the facile observation of polymer dynamics via fluorescence microscopy and thus direct tests of different theories of polymer dynamics. At the same time, they have played a key role in advancing an emerging next-generation method known as genome mapping in nanochannels. The effect of intercalation on the bending energy of DNA as embodied by a change in its statistical segment length (or, alternatively, its persistence length) has been the subject of significant controversy. The precise value of the statistical segment length is critical for the proper interpretation of polymer physics experiments and controls the phenomena underlying the aforementioned genomics technology. In this perspective, we briefly review the model of DNA as a wormlike chain and a trio of methods (light scattering, optical or magnetic tweezers, and atomic force microscopy (AFM)) that have been used to determine the statistical segment length of DNA. We then outline the disagreement in the literature over the role of bisintercalation on the bending energy of DNA, and how a multiscale biomechanical approach could provide an important model for this scientifically and technologically relevant problem.
  • 机译 使用高光谱成像模式进行单细胞分析
    摘要:Almost a decade ago, hyperspectral imaging (HSI) was employed by the NASA in satellite imaging applications such as remote sensing technology. This technology has since been extensively used in the exploration of minerals, agricultural purposes, water resources, and urban development needs. Due to recent advancements in optical re-construction and imaging, HSI can now be applied down to micro- and nanometer scales possibly allowing for exquisite control and analysis of single cell to complex biological systems. This short review provides a description of the working principle of the HSI technology and how HSI can be used to assist, substitute, and validate traditional imaging technologies. This is followed by a description of the use of HSI for biological analysis and medical diagnostics with emphasis on single-cell analysis using HSI.
  • 机译 骨小梁微结构和边界条件简化的差异限制了基于断层扫描的定量计算基于椎骨破坏的有限元模型的准确性
    摘要:Vertebral fractures are common in the elderly, but efforts to reduce their incidence have been hampered by incomplete understanding of the failure processes that are involved. This study's goal was to elucidate failure processes in the lumbar vertebra and to assess the accuracy of quantitative computed tomography (QCT)-based finite element (FE) simulations of these processes. Following QCT scanning, spine segments (n = 27) consisting of L1 with adjacent intervertebral disks and neighboring endplates of T12 and L2 were compressed axially in a stepwise manner. A microcomputed tomography scan was performed at each loading step. The resulting time-lapse series of images was analyzed using digital volume correlation (DVC) to quantify deformations throughout the vertebral body. While some diversity among vertebrae was observed on how these deformations progressed, common features were large strains that developed progressively in the superior third and, concomitantly, in the midtransverse plane, in a manner that was associated with spatial variations in microstructural parameters such as connectivity density. Results of FE simulations corresponded qualitatively to the measured failure patterns when boundary conditions were derived from DVC displacements at the endplate. However, quantitative correspondence was often poor, particularly when boundary conditions were simplified to uniform compressive loading. These findings suggest that variations in trabecular microstructure are one cause of the differences in failure patterns among vertebrae and that both the lack of incorporation of these variations into QCT-based FE models and the oversimplification of boundary conditions limit the accuracy of these models in simulating vertebral failure.
  • 机译 在具有不同分叉角的连续对称气道模型中,动能和粘性耗散对肺吸气和呼气气流中气道阻力的贡献
    摘要:The aim of this study was to investigate and quantify contributions of kinetic energy and viscous dissipation to airway resistance during inspiration and expiration at various flow rates in airway models of different bifurcation angles. We employed symmetric airway models up to the 20th generation with the following five different bifurcation angles at a tracheal flow rate of 20 L/min: 15 deg, 25 deg, 35 deg, 45 deg, and 55 deg. Thus, a total of ten computational fluid dynamics (CFD) simulations for both inspiration and expiration were conducted. Furthermore, we performed additional four simulations with tracheal flow rate values of 10 and 40 L/min for a bifurcation angle of 35 deg to study the effect of flow rate on inspiration and expiration. Using an energy balance equation, we quantified contributions of the pressure drop associated with kinetic energy and viscous dissipation. Kinetic energy was found to be a key variable that explained the differences in airway resistance on inspiration and expiration. The total pressure drop and airway resistance were larger during expiration than inspiration, whereas wall shear stress and viscous dissipation were larger during inspiration than expiration. The dimensional analysis demonstrated that the coefficients of kinetic energy and viscous dissipation were strongly correlated with generation number. In addition, the viscous dissipation coefficient was significantly correlated with bifurcation angle and tracheal flow rate. We performed multiple linear regressions to determine the coefficients of kinetic energy and viscous dissipation, which could be utilized to better estimate the pressure drop in broader ranges of successive bifurcation structures.
  • 机译 表征鼠关节软骨准静态,非线性物质特性的另一种方法
    摘要:With the onset and progression of osteoarthritis (OA), articular cartilage (AC) mechanical properties are altered. These alterations can serve as an objective measure of tissue degradation. Although the mouse is a common and useful animal model for studying OA, it is extremely challenging to measure the mechanical properties of murine AC due to its small size (thickness < 50 μm). In this study, we developed novel and direct approach to independently quantify two quasi-static mechanical properties of mouse AC: the load-dependent (nonlinear) solid matrix Young's modulus (E) and drained Poisson's ratio (ν). The technique involves confocal microscope-based multiaxial strain mapping of compressed, intact murine AC followed by inverse finite element analysis (iFEA) to determine E and ν. Importantly, this approach yields estimates of E and ν that are independent of the initial guesses used for iterative optimization. As a proof of concept, mechanical properties of AC on the medial femoral condyles of wild-type mice were obtained for both trypsin-treated and control specimens. After proteolytic tissue degradation induced through trypsin treatment, a dramatic decrease in E was observed (compared to controls) at each of the three tested loading conditions. A significant decrease in ν due to trypsin digestion was also detected. These data indicate that the method developed in this study may serve as a valuable tool for comparative studies evaluating factors involved in OA pathogenesis using experimentally induced mouse OA models.

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号