首页> 美国卫生研究院文献>International Journal of Molecular Sciences >Spectrophotometric Determination of Phenolic Antioxidants in the Presence of Thiols and Proteins
【2h】

Spectrophotometric Determination of Phenolic Antioxidants in the Presence of Thiols and Proteins

机译:硫醇和蛋白质存在下的分光光度法测定酚类抗氧化剂

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Development of easy, practical, and low-cost spectrophotometric methods is required for the selective determination of phenolic antioxidants in the presence of other similar substances. As electron transfer (ET)-based total antioxidant capacity (TAC) assays generally measure the reducing ability of antioxidant compounds, thiols and phenols cannot be differentiated since they are both responsive to the probe reagent. In this study, three of the most common TAC determination methods, namely cupric ion reducing antioxidant capacity (CUPRAC), 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt/trolox equivalent antioxidant capacity (ABTS/TEAC), and ferric reducing antioxidant power (FRAP), were tested for the assay of phenolics in the presence of selected thiol and protein compounds. Although the FRAP method is almost non-responsive to thiol compounds individually, surprising overoxidations with large positive deviations from additivity were observed when using this method for (phenols + thiols) mixtures. Among the tested TAC methods, CUPRAC gave the most additive results for all studied (phenol + thiol) and (phenol + protein) mixtures with minimal relative error. As ABTS/TEAC and FRAP methods gave small and large deviations, respectively, from additivity of absorbances arising from these components in mixtures, mercury(II) compounds were added to stabilize the thiol components in the form of Hg(II)-thiol complexes so as to enable selective spectrophotometric determination of phenolic components. This error compensation was most efficient for the FRAP method in testing (thiols + phenols) mixtures.
机译:需要开发一种简便,实用和低成本的分光光度法,以在存在其他类似物质的情况下选择性测定酚类抗氧化剂。由于基于电子转移(ET)的总抗氧化剂容量(TAC)分析通常可测量抗氧化剂化合物的还原能力,因此硫醇和酚无法区分,因为它们都对探针试剂有反应。在这项研究中,三种最常用的TAC测定方法,即铜离子还原抗氧化剂容量(CUPRAC),2,2'-叠氮基双(3-乙基苯并噻唑啉-6-磺酸)二铵盐/特洛克斯当量抗氧化剂容量(ABTS / TEAC)在选择的硫醇和蛋白质化合物存在的条件下,对三氧化二铁和还原铁抗氧化能力(FRAP)进行了酚含量测定。尽管FRAP方法几乎对硫醇化合物几乎无反应,但是当使用此方法处理(酚+硫醇)混合物时,会观察到令人惊讶的过氧化,与可加性的偏差较大。在经过测试的TAC方法中,对于所有研究的(酚+硫醇)和(酚+蛋白质)混合物,CUPRAC给出的累加结果最多,相对误差最小。由于ABTS / TEAC和FRAP方法分别对混合物中这些组分产生的吸光度的加和性产生了小偏差和大偏差,因此添加了汞(II)化合物以稳定Hg(II)-硫醇络合物形式的硫醇组分,因此用于选择性分光光度法测定酚类成分。对于FRAP方法测试(硫醇+酚)混合物,这种误差补偿是最有效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号