首页> 美国卫生研究院文献>Journal of Biomolecular Techniques : JBT >Molecular Formula and METLIN Personal Metabolite Database Matching Applied to the Identification of Compounds Generated by LC/TOF-MS
【2h】

Molecular Formula and METLIN Personal Metabolite Database Matching Applied to the Identification of Compounds Generated by LC/TOF-MS

机译:分子式和METLIN个人代谢物数据库匹配用于鉴定LC / TOF-MS生成的化合物

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In an effort to simplify and streamline compound identification from metabolomics data generated by liquid chromatography time-of-flight mass spectrometry, we have created software for constructing Personalized Metabolite Databases with content from over 15,000 compounds pulled from the public METLIN database (). Moreover, we have added extra functionalities to the database that (a) permit the addition of user-defined retention times as an orthogonal searchable parameter to complement accurate mass data; and (b) allow interfacing to separate software, a Molecular Formula Generator (MFG), that facilitates reliable interpretation of any database matches from the accurate mass spectral data. To test the utility of this identification strategy, we added retention times to a subset of masses in this database, representing a mixture of 78 synthetic urine standards. The synthetic mixture was analyzed and screened against this METLIN urine database, resulting in 46 accurate mass and retention time matches. Human urine samples were subsequently analyzed under the same analytical conditions and screened against this database. A total of 1387 ions were detected in human urine; 16 of these ions matched both accurate mass and retention time parameters for the 78 urine standards in the database. Another 374 had only an accurate mass match to the database, with 163 of those masses also having the highest MFG score. Furthermore, MFG calculated a formula for a further 849 ions that had no match to the database. Taken together, these results suggest that the METLIN Personal Metabolite database and MFG software offer a robust strategy for confirming the formula of database matches. In the event of no database match, it also suggests possible formulas that may be helpful in interpreting the experimental results.
机译:为了简化和简化由液相色谱飞行时间质谱仪产生的代谢组学数据进行化合物鉴定,我们创建了用于构建个性化代谢物数据库的软件,该数据库包含从METLIN公共数据库中提取的15,000多种化合物。而且,我们为数据库增加了额外的功能,(a)允许添加用户定义的保留时间作为正交的可搜索参数,以补充准确的质量数据; (b)允许与单独的软件分子式生成器(MFG)进行接口,该软件可以从准确的质谱数据中可靠地解释任何数据库匹配。为了测试这种鉴定策略的效用,我们在该数据库中的一部分质量中增加了保留时间,代表了78种合成尿液标准品的混合物。对合成混合物进行分析,并根据该METLIN尿液数据库进行筛选,得出46个准确的质量和保留时间匹配。随后在相同的分析条件下分析人尿液样品,并对照该数据库进行筛选。人体尿液中总共检测到1387个离子;这些离子中的16个与数据库中78个尿液标准品的准确质量和保留时间参数均匹配。另外374个与数据库只有精确的质量匹配,其中163个质量也具有最高的MFG得分。此外,MFG还计算了与数据库不匹配的另外849个离子的公式。综上所述,这些结果表明,METLIN个人代谢物数据库和MFG软件为确认数据库匹配公式提供了可靠的策略。在没有数据库匹配的情况下,它还建议可能的公式,这些公式可能有助于解释实验结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号