Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

机译:腰椎成像中入口表面剂量和不同器官剂量的研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. >Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. >Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. >Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. >Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100.
机译:>背景:使用合适的剂量计进行剂量评估对于放射防护的优化和放射诊断学的影像学依据尤其重要。 >目的:该研究的目的是使用两个热致发光剂量计TLD-100(LiF:Mg,Ti)和GR-200(LiF)获得接受腰椎成像的患者的入院皮肤剂量(ESD) :Mg,Cu,P),并在腰椎成像中获得对不同器官的吸收剂量的几种观点。 >方法:为了测量接受腰椎成像的患者的ESD值,将两种TLD类型放置在他们的皮肤表面上。通过将TLD放置在Rando体模的表面,还可以测量不同腰椎影像的ESD值。将几个TLD芯片插入Rando体模的不同器官中,以测量腰椎成像中不同器官的吸收剂量。 >结果:结果表明两个剂量计的结果之间存在密切的一致性。根据该实验的结果,本研究中包括的16名患者的ESD剂量在2.71 mGy和26.29 mGy之间变化,而TLD-100的平均值为11.89 mGy,在2.55 mGy和27.41 mGy之间变化,平均为12.32 mGy。适用于GR-200测量。通过将两种类型的TLD放置在Rando体模的表面而获得的ESD密切相关。 >结论:根据结果,GR200的灵敏度高于TLD-100。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号