首页> 美国卫生研究院文献>Materials >In Vitro Comparison between Metal Sleeve-Free and Metal Sleeve-Incorporated 3D-Printed Computer-Assisted Implant Surgical Guides
【2h】

In Vitro Comparison between Metal Sleeve-Free and Metal Sleeve-Incorporated 3D-Printed Computer-Assisted Implant Surgical Guides

机译:金属套筒和金属套管合并的3D印刷计算机辅助植入手术指南的体外比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study aims to compare the accuracy of metal sleeve-free 3D-printed computer-assisted implant surgical guides (MSF group) (n = 10) with metal sleeve-incorporated 3D-printed computer-assisted implant surgical guides (MSI group) (n = 10). Implants of diameter 4.0 mm and 5.0 mm were placed in the left second premolars and bilateral first molars, respectively, using a fully guided system. Closed-form sleeves were used in teeth on the left and open-form sleeves on the right. The weight differences of the surgical guides before and after implant placement, and angular deviations before and after implant placement were measured. Weight differences were compared with Student’s t-tests and angular deviations with Mann–Whitney tests. Cross-sectional views of the insert parts were observed with a scanning electron microscope. Preoperative and postoperative weight differences between the two groups were not statistically significant (p = 0.821). In terms of angular deviations, those along the mesiodistal direction for the left second premolars were significantly lower in the MSF group (p = 0.006). However, those along the mesiodistal direction for the bilateral molars and those along the buccolingual direction for all teeth were not significantly different (p > 0.05). 3D-printed implant surgical guides without metal sleeve inserts enable accurate implant placement without exhausting the guide holes, rendering them feasible for fully guided implant placement.
机译:本研究旨在将金属套筒3D印刷计算机辅助植入手术指南(MSF组)(N = 10)的准确性与金属套筒合并的3D印刷的计算机辅助植入外科手术指南(MSI组)进行比较(MSF组)(N = 10)( n = 10)。使用完全引导的系统,分别在左下第二初级初级和双侧第一磨牙中置于左上第二初级和双侧第一磨牙植物。封闭式套管用于左侧的牙齿和右侧的开放式套管。测量植入物放置前后的手术指导和植入物放置前后角偏差的重量差异。将体重差异与学生的T-Tests和与Mann-Whitney测试的角度偏差进行比较。用扫描电子显微镜观察插入件的横截面视图。两组之间的术前和术后重量差异在统计学上没有统计学意义(P = 0.821)。在角度偏差方面,MSF组沿着左第二初级初级前运动方向的那些显着较低(P = 0.006)。然而,沿双侧臼齿的关系方向的那些和沿着所有牙齿的Buccoling方向的那些没有显着差异(p> 0.05)。 3D印刷的植入物外科手术导向器没有金属套筒插入物,可以精确的植入物放置,而无需耗尽引导孔,使它们可用于完全引导的植入物放置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号