首页> 美国卫生研究院文献>Polish Journal of Microbiology >Evaluation of Modified Hodge Test as a Non-molecular Assay for Accurate Detection of KPC-producing Klebsiella pneumoniae
【2h】

Evaluation of Modified Hodge Test as a Non-molecular Assay for Accurate Detection of KPC-producing Klebsiella pneumoniae

机译:改进的霍奇试验作为一种准确检测生产KPC的肺炎克雷伯菌的非分子分析方法的评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

carbapenemase (KPC) have become a major therapeutic challenge because of its increasingly fast dissemination throughout the world. Accurate detection of KPC is essential for optimal treatment. The Clinical and Laboratory Standards Institutes (CLSI) for fast detection of KPC producers currently recommend Modified Hodge Test (MHT) and Carba NP test. MHT can directly detect carbapenemase production in isolates. The current study was conducted to evaluate the capacity of MHT with two carbapenem disks for accurate detection of KPC. MHT was performed according to guidelines of CLSI to identify isolates with carbapenem resistance. In doing so, two substrates of MHT were assigned into two groups for examination: meropenem and ertapenem groups. A total of 96 non-repetitive clinical isolates of were tested. The presence of the gene in each MHT-positive isolate was examined by PCR. A total of 54 isolates exhibited reduced susceptibility or resistance to carbapenems. Sensitivity of MHT with two carbapenem disks was similar. Specificity of the MHT with meropenem disk was 64% and with ertapenem disk was 53%. Detection of KPC by MHT with meropenem disk was found to be more effective than with ertapenem disk. Based on our results, the presence of KPC does not in itself influence the categorization of resistance. Therefore, the use of MHT with ertapenem disk for the rapid detection of KPC among for infection control should not be recommended.
机译:碳青霉烯酶(KPC)由于其在世界范围内日益迅速的传播而成为一项重大的治疗挑战。准确检测KPC对于最佳治疗至关重要。用于快速检测KPC生产者的临床和实验室标准协会(CLSI)当前建议使用改良的Hodge测试(MHT)和Carba NP测试。 MHT可以直接检测分离物中的碳青霉烯酶生产。目前的研究是用两个碳青霉烯盘评估MHT的能力,以准确检测KPC。根据CLSI指南进行MHT,以鉴定具有碳青霉烯抗性的分离株。为此,将MHT的两种底物分为两组进行检查:美罗培南和厄他培南组。总共测试了96种非重复性临床分离株。通过PCR检查每个MHT阳性分离物中该基因的存在。总共54个分离株表现出对碳青霉烯类药物的敏感性降低。两个碳青霉烯膜对MHT的敏感性相似。美罗培南片对MHT的特异性为64%,厄他培南片对MHT的特异性为53%。发现用美罗培南磁盘通过MHT检测KPC比使用厄他培南磁盘更有效。根据我们的结果,KPC的存在本身并不影响电阻的分类。因此,不建议使用带有厄他培南磁盘的MHT来快速检测KPC以控制感染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号