Accurate identification and antimicrobial susceptibility testing (AST) of nonfermenters from cystic fibrosis patients are essential for appropriate antimicrobial treatment. This study examined the ability of the newly designed Vitek 2 nonfermenting gram-negative card (NGNC) (new gram-negative identification card; bioMérieux, Marcy-l'Ètoile, France) to identify nonfermenting gram-negative rods from cystic fibrosis patients in comparison to reference methods and the accuracy of the new Vitek 2 version 4.02 software for AST compared to the broth microdilution method. Two hundred twenty-four strains for identification and 138 strains for AST were investigated. The Vitek 2 NGNC identified 211 (94.1%) of the nonfermenters correctly. Among morphologically atypical microorganisms, five strains were misidentified and eight strains were determined with low discrimination, requiring additional tests which raised the correct identification rate to 97.8%. Regarding AST, the overall essential agreement of Vitek 2 was 97.6%, and the overall categorical agreement was 92.9%. Minor errors were found in 5.1% of strains, and major and very major errors were found in 1.6% and 0.3% of strains, respectively. In conclusion, the Vitek NGNC appears to be a reliable method for identification of morphologically typical nonfermenters and is an improvement over the API NE system and the Vitek 2 GNC database version 4.01. However, classification in morphologically atypical nonfermenters must be interpreted with care to avoid misidentification. Moreover, the new Vitek 2 version 4.02 software showed good results for AST and is suitable for routine clinical use. More work is needed for the reliable testing of strains whose MICs are close to the breakpoints.
机译:正确鉴定和囊性纤维化患者非发酵剂的药敏试验(AST)对于适当的抗菌治疗至关重要。这项研究检查了新设计的Vitek 2非发酵革兰阴性卡(NGNC)(新的革兰氏阴性识别卡;bioMérieux,Marcy-l'Ètoile,法国)从囊性纤维化患者中鉴定非发酵革兰氏阴性棒的能力,以进行比较与肉汤微稀释法相比,可以参考AST的新Vitek 2 4.02版软件的方法和准确性。研究了用于鉴定的224个菌株和用于AST的138个菌株。 Vitek 2 NGNC正确识别了211个非发酵罐(94.1%)。在形态学非典型微生物中,五种菌株被错误鉴定,低辨别度确定了八种菌株,需要进行额外的测试,从而将正确的鉴定率提高到97.8%。关于AST,Vitek 2的总体必要协议为97.6%,总体分类协议为92.9%。在5.1%的菌株中发现了较小的错误,在1.6%和0.3%的菌株中分别发现了主要和非常主要的错误。总之,Vitek NGNC似乎是鉴定形态学典型非发酵剂的可靠方法,并且是对API NE系统和Vitek 2 GNC数据库版本4.01的改进。但是,在形态学上非典型的非发酵罐中的分类必须谨慎解释,以避免错误识别。此外,新的Vitek 2版本4.02软件对AST表现出良好的效果,适合常规临床使用。为了可靠地测试MIC接近断点的菌株,还需要做更多的工作。