首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparison of commercial enzyme immunoassay kits with plaque reduction neutralization test for detection of measles virus antibody.
【2h】

Comparison of commercial enzyme immunoassay kits with plaque reduction neutralization test for detection of measles virus antibody.

机译:商业酶免疫测定试剂盒与斑块减少中和测试用于检测麻疹病毒抗体的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Four commercially available enzyme immunoassay (EIA) kits were evaluated in comparison with the plaque reduction neutralization (PRN) test for detection of measles virus antibody. The EIA kits, Enzygnost (Behring), Diamedix, Vidas (bioMerieux Vitek), and Measlestat (Biowhittaker), were assessed with two PRN cutoff titers: a PRN titer of 8, the lowest detectable antibody level by the PRN test under the test conditions, and a titer of 120, which has been shown to be the minimum protective antibody titer. At a PRN cutoff titer of 8, the sensitivity was 88.2, 91.1, 74.6, and 69.8% for Behring, Diamedix, Vidas, and Biowhittaker EIA tests, respectively, with negative predictive values ranging from 22.7 to 45.5%. The specificity was 93.8% for Diamedix and 100% for the rest. At a PRN cutoff titer of 120, the sensitivity and specificity, respectively, were 100 and 90.7% (Behring), 98.2 and 58.8% (Diamedix), 90.6 and 94.5% (Vidas), and 85.7 and 96.4% (Biowhittaker). At this PRN cutoff titer, the negative predictive values of all EIA tests improved considerably, ranging from 70.7 to 100%. The EIA results showed an excellent association with PRN results when the PRN titers of the test samples were either < 8 or > 1,052. Discrepancies occurred especially when testing samples having PRN titers in the range of 8 to 120, indicating lack of sensitivity of the EIA tests in detecting measles virus antibody at low levels. Maternally derived measles virus antibody at this level has been shown to interfere with measles vaccine response in children and hence has implications from the standpoint of measles immunization.(ABSTRACT TRUNCATED AT 250 WORDS)
机译:与用于检测麻疹病毒抗体的噬斑减少中和(PRN)测试相比,评估了四种市售的酶免疫测定(EIA)试剂盒。 EIA试剂盒Enzygnost(Behring),Diamedix,Vidas(bioMerieux Vitek)和Measlestat(Biowhittaker)用两种PRN截止效价进行了评估:PRN效价为8,在测试条件下通过PRN测试可检测到的最低抗体水平,且效价为120,已证明是最低的保护性抗体效价。在PRN截止效价为8时,Behring,Diamedix,Vidas和Biowhittaker EIA测试的敏感性分别为88.2、91.1、74.6和69.8%,阴性预测值范围为22.7至45.5%。 Diamedix的特异性为93.8%,其余为100%。在PRN截止效价为120时,灵敏度和特异性分别为100和90.7%(贝林),98.2和58.8%(Diamedix),90.6和94.5%(Vidas),85.7和96.4%(Biowhittaker)。在此PRN临界滴定度下,所有EIA测试的阴性预测值均显着提高,范围从70.7至100%。当测试样品的PRN滴度<8或> 1,052时,EIA结果与PRN结果具有极好的关联。差异特别是在测试PRN滴度在8至120范围内的样品时出现,这表明EIA测试缺乏检测低水平麻疹病毒抗体的敏感性。已证明这种水平的母源性麻疹病毒抗体会干扰儿童的麻疹疫苗反应,因此从麻疹免疫的角度来看具有一定意义。(摘要截短为250字)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号