首页> 美国卫生研究院文献>other >Comparison of Two Automated Solid Phase Extractions for the Detection of Ten Fentanyl Analogs and Metabolites in Human Urine Using Liquid Chromatography Tandem Mass Spectrometry
【2h】

Comparison of Two Automated Solid Phase Extractions for the Detection of Ten Fentanyl Analogs and Metabolites in Human Urine Using Liquid Chromatography Tandem Mass Spectrometry

机译:液相色谱串联质谱法检测人尿中十种芬太尼类似物和代谢物的两种自动化固相萃取方法的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Two types of automated solid phase extraction (SPE) were assessed for the determination of human exposure to fentanyls in urine. High sensitivity is required to detect these compounds following exposure because of the low dose required for therapeutic effect and the rapid clearance from the body for these compounds. To achieve this sensitivity, two acceptable methods for the detection of human exposure to seven fentanyl analogs and three metabolites were developed using either off-line 96-well plate SPE or on-line SPE. Each system offers different advantages: off-line 96-well plate SPE allows for high throughput analysis of many samples, which is needed for large sample numbers, while on-line SPE removes almost all analyst manipulation of the samples, minimizing the analyst time needed for sample preparation. Both sample preparations were coupled with reversed phase liquid chromatography and isotope dilution tandem mass spectrometry (LC-MS/MS) for analyte detection. For both methods, the resulting precision was within 15%, the accuracy within 25%, and the sensitivity was comparable with the limits of detection ranging from 0.002-0.041ng/mL. Additionally, matrix effects were substantially decreased from previous reports for both extraction protocols. The results of this comparison showed that both methods were acceptable for the detection of exposures to fentanyl analogs and metabolites in urine.
机译:评估了两种类型的自动固相萃取(SPE),用于确定人体对尿液中芬太尼的暴露程度。由于治疗效果所需的低剂量以及这些化合物从体内的快速清除,在暴露后检测这些化合物需要很高的灵敏度。为了达到这种敏感性,使用离线96孔板SPE或在线SPE,开发了两种可接受的检测人体暴露于7种芬太尼类似物和3种代谢物的方法。每种系统都有不同的优势:离线96孔板SPE可以对许多样品进行高通量分析,这是大量样品所需的,而在线SPE则几乎消除了所有分析人员对样品的操作,从而最大限度地减少了分析人员所需的时间用于样品制备。两种样品前处理均采用反相液相色谱和同位素稀释串联质谱(LC-MS / MS)进行分析物检测。对于这两种方法,所得的精度均在15%之内,精度在25%之内,并且灵敏度与0.002-0.041ng / mL的检测限相当。此外,与以前的报告相比,两种提取方案的基质效应均大大降低。比较结果表明,两种方法均可用于检测尿液中芬太尼类似物和代谢物的暴露。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号