首页> 美国卫生研究院文献>other >Hyperspectral Image Mapping Spectrometry for Retinal Oximetry Measurements in Four Diseased Eyes
【2h】

Hyperspectral Image Mapping Spectrometry for Retinal Oximetry Measurements in Four Diseased Eyes

机译:高光谱图像映射光谱法用于四只患病眼的视网膜血氧饱和度测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We describe the hyperspectral Image Mapping Spectrometer (IMS) which is able to acquire spectral images of the retina with no scanning components. We then utilize this technology to obtain absolute oxygen saturation measurements in four patients with retinal diseases. The IMS acquires spatial and spectral information of a scene in a single camera exposure time. The IMS is attached to the port of a Topcon TRC-50EX funduscopic camera in order to acquire images. The IMS has high spatial (350×350) and spectral sampling (40), and avoids motion artifacts associated with eye movements. Oximetry values are obtained by measuring the absorption of retinal blood. Four patients with different retinal diseases were imaged via the IMS in this study. Oxygen saturation is calculated using a least squares fit applied to the whole blood oximetry equation. Oxygen saturation was found to be 88.6% (±1.9) and 34.1% (±7.0) for the artery and vein, respectively, in a patient with non-exudative age-related macular degeneration (AMD) with borderline glaucoma, 100.0% (±0.0) and 50.4% (±8.2) in a patient with exudative AMD, 100.0% (±0.0) and 45.2% (±7.0) in a patient with retinitis pigmentosa, and 94.1% (±2.5) and 44.9% (±5.6) in a patient with chronic iridocyclitis. These values are consistent with previously published data. Based on spatial and spectral data, we created an oxygen saturation map with oxygenation data overlying retinal vasculature. Hyperspectral imaging may be a promising way to measure retinal oxygen saturation. IMS technology is advantageous in its ability to obtain images free of motion artifacts.
机译:我们描述了高光谱图像映射光谱仪(IMS),它能够获取没有扫描成分的视网膜光谱图像。然后,我们利用这项技术获得四名视网膜疾病患者的绝对氧饱和度测量值。 IMS在单个摄像机曝光时间内获取场景的空间和光谱信息。 IMS连接到Topcon TRC-50EX阴道镜相机的端口,以获取图像。 IMS具有较高的空间(350×350)和频谱采样(40),并避免了与眼睛运动相关的运动伪像。血氧饱和度值通过测量视网膜血液的吸收来获得。在这项研究中,通过IMS对四名患有不同视网膜疾病的患者进行了成像。使用应用于全血氧饱和度方程的最小二乘拟合来计算氧饱和度。在患有非渗出性年龄相关性黄斑变性(AMD)的交界性青光眼患者中,发现动脉和静脉的氧饱和度分别为88.6%(±1.9)和34.1%(±7.0)。渗出性AMD患者为0.0)和50.4%(±8.2),色素性视网膜炎患者为10​​0.0%(±0.0)和45.2%(±7.0),以及94.1%(±2.5)和44.9%(±5.6)在患有慢性虹膜睫状体炎的患者中。这些值与以前发布的数据一致。根据空间和光谱数据,我们创建了一个氧饱和度图,其中氧合数据覆盖了视网膜脉管系统。高光谱成像可能是测量视网膜氧饱和度的一种有前途的方法。 IMS技术在获得无运动伪影的图像的能力方面具有优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号