首页> 美国卫生研究院文献>other >Ideal parameters for femto-second laser-assisted anterior capsulotomy: Animal studies
【2h】

Ideal parameters for femto-second laser-assisted anterior capsulotomy: Animal studies

机译:飞秒激光辅助前囊切开术的理想参数:动物研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In femtosecond laser-assisted cataract surgery, the parameter such as horizontal spot spacing and energy level can be adjusted. Although there have been several studies reported on various laser systems, showing the effects of varying energy levels and horizontal spot spacing on lens capsulotomy cut edges, none have been reported on the Catalys laser system (Abbott Medical Optics, Inc., Santa Ana, CA). The aim of this study is to evaluate, using scanning electron microscopy (SEM), the quality of the cut edges of the laser lens capsulotomy obtained using the Catalys Laser System, using different horizontal spot spacing and energy levels, and to determine the ideal parameters based on SEM results. Fifty rabbit capsulorhexis specimens from a femtosecond laser with different spot spacing and energy settings were divided into five groups randomly. Spot spacing was 3 um and laser pulse energy was 4 uJ in group 1. The respective values were 5 um and 2 uJ in group 2, 5 um and 4 uJ in group 3, 5 um and 6 uJ in group 4, and 7 um and 4 uJ in group 5. All samples were evaluated using SEM to compare the number of tags per capsulotomy and the laser emission time. Group 1 had a significantly lower tag formation than groups 3 and 5 (P = 0.042 and 0.021, respectively). Although the laser emission time increased about 1.5 sec as the spot spacing increased from 3 to 7 um, the quality of the cut was smoother in group 1 because of overlapping effect of photodisruption cavities. There was no significant difference between groups 2, 3 and 4 at different laser energy settings. In an ex-vivo study, samples from an energy setting of 10 uJ showed increased irregularity and damage. The degree of irregularity was higher at increasing spot spacing and laser energy settings, with abundant tag formation. Dense spot spacing with low-energy settings provide a better cut quality, which is probably correlated with the reduction in anterior capsular tear complications.
机译:在飞秒激光辅助白内障手术中,可以调整水平光斑间距和能量水平等参数。尽管有几项研究针对各种激光系统进行了报道,显示出不同的能量水平和水平光斑间距对晶状体切开切开切口边缘的影响,但有关Catalys激光系统的报道均未见报道(Abbott Medical Optics,Inc.,Santa Ana,CA )。本研究的目的是使用扫描电子显微镜(SEM)评估使用Catalys Laser System获得的激光晶状体切开术的切割边缘的切割质量,并使用不同的水平光斑间距和能级,并确定理想的参数根据SEM结果。用飞秒激光将五十只来自不同间隔和能量设置的飞秒激光兔撕囊标本随机分为五组。第1组的光点间距为3 um,激光脉冲能量为4 uJ。第2组的分别为5 um和2 uJ,第3组的分别为5 um和4 uJ,第4组的为5 um和6 uJ,第4组为7 um在第5组中为4 uJ。所有样品均使用SEM进行评估,以比较每次切囊术的标签数量和激光发射时间。第1组的标记形成明显低于第3组和第5组(分别为P = 0.042和0.021)。尽管随着光点间距从3微米增加到7微米,激光发射时间增加了约1.5秒,但由于光分裂腔的重叠效应,第1组的切割质量更加平滑。在不同的激光能量设置下,第2、3和4组之间没有显着差异。在一项离体研究中,能量设定为10 uJ的样品显示出增加的不规则性和损伤。在增加光点间距和激光能量设置时,不规则程度较高,并形成大量标签。低能量设置下的密集斑点间距可提供更好的切割质量,这可能与前囊撕裂并发症的减少相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号