首页> 美国卫生研究院文献>other >Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data
【2h】

Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data

机译:使用双层光谱CT从造影剂冠状动脉计算机断层扫描血管造影术计算钙评分的准确性:真实和虚拟非对比数据钙评分的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PurposeModern non-invasive evaluation of Coronary Artery Disease (CAD) requires non-contrast low dose Computed Tomography (CT) imaging for determination of Calcium Scoring (CACS) and contrast-enhanced imaging for evaluation of vascular stenosis. Several methods for calculation of CACS from contrast-enhanced images have been proposed before. The main principle for that is generation of virtual non-contrast images by iodine subtraction from a contrast-enhanced spectral CT dataset. However, those techniques have some limitations: Dual-Source CT imaging can lead to increased radiation exposure, and switching of the tube voltage (rapid kVp switching) can be associated with slower rotation speed of the gantry and is thus prone to motion artefacts that are especially critical in cardiac imaging. Both techniques cannot simultaneously acquire spectral data. A novel technique to overcome these difficulties is spectral imaging with a dual-layer detector. After absorption of the lower energetic photons in the first layer, the second layer detects a hardened spectrum of the emitted radiation resulting in registration of two different energy spectra at the same time. The objective of the present investigation was to evaluate the accuracy of virtual non-contrast CACS computed from spectral data in comparison to standard non-contrast imaging.
机译:目的现代无创评估冠状动脉疾病(CAD)要求使用非对比低剂量计算机断层扫描(CT)成像来确定钙评分(CACS),并使用对比增强成像来评估血管狭窄。以前已经提出了几种从对比度增强图像计算CACS的方法。其主要原理是通过从对比度增强的光谱CT数据集中减去碘来生成虚拟的非对比度图像。但是,这些技术有一些局限性:双源CT成像可能导致增加的辐射暴露,并且管电压的切换(快速kVp切换)可能与门架的旋转速度降低有关,因此容易产生运动伪影。在心脏成像中尤其重要。两种技术不能同时获取光谱数据。克服这些困难的一种新颖技术是使用双层探测器进行光谱成像。在第一层吸收了较低的高能光子之后,第二层检测到发射辐射的硬化光谱,从而同时记录了两个不同的能谱。本研究的目的是评估与标准非造影成像相比,从光谱数据计算得出的虚拟非造影CACS的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号