To generate a patient-friendly, time-efficient cardiac MRI examination protocol, a highly accelerated real-time CINE MR sequence (SSIR) was acquired in the idle time in between contrast injection and late gadolinium enhancement phase. 20 consecutive patients underwent a cardiac MRI examination including a multi-breath-hold sequence as gold standard (Ref) as well as SSIR sequences with (SSIR-BH) and without breath-hold (SSIR-nonBH). SSIR sequences were acquired 4 minutes after gadolinium injection. Right- (RV) and left-ventricular (LV) volumetric functional parameters were evaluated and compared between Ref and SSIR sequences. Despite reduced contrast between myocardium and intra-ventricular blood, volumetric as well as regional wall movement assessment revealed high agreement between both SSIR sequences and Ref. Excellent correlation and narrow limits of agreements were found for both SSIR-BH and SSIR-nonBH when compared to Ref for both LV (mean LV ejection fraction [EF] Ref: 52.8 ± 12.6%, SSIR-BH 52.3 ± 12.9%, SSIR-nonBH 52.5 ± 12.6%) and RV (mean RV EF Ref: 52.7 ± 9.4%, SSIR-BH 52.0 ± 8.1%, SSIR-nonBH 52.2 ± 9.3%) analyses. Even when acquired in the idle time in between gadolinium injection and LGE acquisition, the highly accelerated SSIR sequence delivers accurate volumetric and regional wall movement information. It thus seems ideal for very time-efficient and robust cardiac MR imaging protocols.
机译:为了生成对患者友好,省时的心脏MRI检查方案,在造影剂注射和g增强阶段之间的空闲时间中获得了高度加速的实时CINE MR序列(SSIR)。连续20例患者接受了心脏MRI检查,包括多呼吸屏风序列作为金标准(Ref)以及具有(SSIR-BH)和不屏气(SSIR-nonBH)的SSIR序列。 injection注射后4分钟获得SSIR序列。评估右(RV)和左心室(LV)的容积功能参数,并在Ref和SSIR序列之间进行比较。尽管心肌和心室内血之间的对比度降低,但是容积和区域壁运动评估显示SSIR序列与参考文献之间具有高度一致性。与两个LV的Ref相比,SSIR-BH和SSIR-nonBH均具有出色的相关性和狭窄的协议限制(平均LV射血分数[EF] Ref:52.8±12.6%,SSIR-BH 52.3±12.9%,SSIR- nonBH 52.5%±12.6%)和RV(平均RV EF参考:52.7%±9.4%,SSIR-BH 52.0%±8.1%,SSIR-nonBH 52.2%±9.3%)分析。即使在injection注入和LGE采集之间的空闲时间内进行采集,高度加速的SSIR序列也可以提供准确的体积和区域壁运动信息。因此,对于非常省时且健壮的心脏MR成像协议而言,这似乎是理想的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号