Evaluation of the response of breast cancer patients to neoadjuvant chemotherapy by combined contrast-enhanced ultrasonography and ultrasound elastography

机译:超声造影与超声弹性成像相结合评估乳腺癌患者对新辅助化疗的反应

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of the present study was to investigate whether contrast-enhanced ultrasonography (CEUS) in combination with ultrasound elastography (UE) is able to accurately predict the efficacy of neoadjuvant chemotherapy (NAC) in breast cancer patients. A total of 65 breast cancer patients who received NAC at the First Affiliated Hospital of Zhejiang University (Hangzhou, China) between February 2016 and August 2017 and were recruited for the present study. Prior to and after NAC, examination by CEUS, UE or their combination was performed. Pathological results were obtained at the end of each chemotherapy cycle, based on which 41 cases were assigned to the response group and 24 to the non-response group. Kappa values were 0.710, 0.434 and 0.836 for CEUS, UE and CEUS+UE, respectively. The area under the receiver operating characteristic curves for CEUS, UE and CEUS+UE for determining the response to NAC was 0.864 [95% confidence interval (CI), 0.765–0.964], 0.715 (95% CI, 0.579–0.850) and 0.910 (95% CI, 0.826–0.993), respectively. It was identified that the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of CEUS+UE were higher than those of CEUS and US individually. The prediction accuracy was 89.2, 90.8 and 100% for CEUS, UE and their combination, respectively. CEUS and UE have their own advantages in evaluating the clinical efficacy of NAC in breast cancer, and a higher accuracy was achieved when the two techniques were applied in combination. Therefore, a combination of CEUS and UE may be a preferred method for the clinical assessment of the efficacy of NAC in breast cancer patients.
机译:本研究的目的是研究对比增强超声(CEUS)与超声弹性成像(UE)相结合是否能够准确预测乳腺癌新辅助化疗(NAC)的疗效。在2016年2月至2017年8月期间,共65例在浙江大学附属第一医院(中国杭州)接受NAC的乳腺癌患者入选本研究。在NAC之前和之后,进行了CEUS,UE或其组合的检查。在每个化疗周期结束时获得病理结果,根据该结果将41例患者归为响应组,将24例归为无响应组。 CEUS,UE和CEUS + UE的Kappa值分别为0.710、0.434和0.836。用于确定对NAC响应的CEUS,UE和CEUS + UE的接收机工作特性曲线下的面积为0.864 [95%置信区间(CI),0.765-0.964],0.715(95%CI,0.579-0.850)和0.910 (95%CI,0.826-0.993)。结果表明,CEUS + UE的敏感性,特异性,准确性,阳性预测值和阴性预测值均高于CEUS和US。 CEUS,UE及其组合的预测准确度分别为89.2、90.8和100%。 CEUS和UE在评估NAC在乳腺癌中的临床疗效方面具有各自的优势,并且将这两种技术结合使用可以达到更高的准确性。因此,CEUS和UE的组合可能是临床评估NAC在乳腺癌患者中疗效的首选方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号