Eighty-nine grafts of expanded microporous polytetrafluoroethylene (PTFE) with a diameter of 4 mm, were placed in the carotid and femoral arteries of dogs. The animals were sacrificed at varying intervals beginning three days after operation. Four animals remain alive with patent grafts 10 months post-operatively. Twenty-four of 89 grafts were occluded, an overall patency of 73%. Fibril length (pore size) of the graft material was varied from 4 to 110 microns. Average pore size ranged from 9 to 65 microns. Wall thickness varied from 0.3 to 0.75 mm. Density ranged from 0.24 to 0.35 g/ml. Tissue ingrowth, neointimization and patency rate as compared to pore size, wall-thickness and density of expanded PTFE were observed. Pore size is the primary determinant of tissue ingrowth, neointimization and patency. Of 51 grafts with an average pore size of 22 microns or less, there were 6 occlusions, an 88% patency rate. There were 38 grafts with an average pore size of 34 microns or greater. In these 38 grafts, 18 occlusions were observed, a 53% patency rate. Patent grafts demonstrated tissue ingrowth, capillary formation an a thin neointima. Using small pore grafts, patency rates of 90% can be anticipated in the dog. Expanded microporous PTFE with its ease of handling, strength and pliability may be the vascular prosthesis of choice in man.
机译:将八十九只直径为4毫米的膨化微孔聚四氟乙烯(PTFE)移植物植入犬的颈动脉和股动脉。手术后三天开始以不同间隔处死动物。术后10个月,有四只动物通过专利移植物存活。 89个移植物中有24个被阻塞,总通畅率为73%。移植材料的原纤维长度(孔径)在4至110微米之间变化。平均孔径为9至65微米。壁厚从0.3到0.75毫米不等。密度范围为0.24至0.35 g / ml。观察到与长孔,壁厚和膨胀PTFE的密度相比,组织向内生长,新刺激和通畅率。孔的大小是组织向内生长,新刺激和通畅的主要决定因素。在51个平均孔径为22微米或更小的移植物中,有6个咬合,通畅率为88%。有38个移植物,平均孔径为34微米或更大。在这38个移植物中,观察到18个咬合,通畅率为53%。专利移植物显示组织向内生长,毛细血管形成薄的新内膜。使用小孔移植物,可以预期狗的通畅率为90%。膨胀的微孔PTFE易于处理,强度和柔韧性可能是人类选择的人工血管。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号