A total of 222 clinical isolates were used to test the accuracy of Sensititre dried microtitration trays for determining minimum inhibitory concentrations (MICs) of antimicrobial agents. In comparison with an agar dilution technique, 89.5% of all the pairs of results were within one doubling dilution. The 2,420 pairs of MIC results with finite values gave a corresponding figure of 86.8%. Exclusion of sulfisoxazole results, which demonstrated a significant interlaboratory variation in accuracy, raised this value to 89.1%. Very good differentiation of beta-lactamase-producing strains of Staphylococcus aureus (24 of 24 giving an MIC greater than or equal to 0.25 micrograms/ml) and Haemophilus influenzae (3 of 3 giving an MIC greater than or equal to 32 micrograms/ml) was obtained with the Sensititre system. This method also clearly distinguished erythromycin-resistant S. aureus strains (7 of 7 giving an MIC greater than 32 micrograms/ml) from the susceptible strains (26 of 28 giving an MIC less than or equal to 0.5 microgram/ml plus 1 strain at 1.0 microgram/ml and 1 at 2.0 micrograms/ml). Sensititre offers an accurate and convenient method of determining MICs comparable to those obtained with the agar dilution procedure, with the advantage of an extended shelf life when stored at room temperature.
机译:总共222种临床分离株用于测试Sensititre干式微量滴定盘的准确性,以确定抗菌剂的最小抑菌浓度(MIC)。与琼脂稀释技术相比,所有结果对中有89.5%位于一倍稀释范围内。 2,420对具有有限值的MIC结果给出了对应的86.8%的数字。排除了异异恶唑的结果,该结果表明实验室间的准确性差异很大,将该值提高到89.1%。产生β-内酰胺酶的金黄色葡萄球菌菌株(24个中的24个,MIC大于或等于0.25微克/毫升)和流感嗜血杆菌(3个中的3个,其MIC大于或等于32微克/毫升)的很好的区分是使用Sensititre系统获得的。该方法还明确区分了耐红霉素金黄色葡萄球菌菌株(7个中的7个,MIC大于32微克/毫升)与易感菌株(28个中的26个,其MIC小于或等于0.5微克/毫升,另加1个菌株。 1.0微克/毫升和1个2.0微克/毫升)。 Sensititre提供了一种准确,方便的测定MIC的方法,可与琼脂稀释程序相比,并且在室温下保存时具有更长的保存期限。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号