AIMS/BACKGROUND: The intentions of this study were to estimate agreement between two different autorefractors and standard subjective refraction techniques and to evaluate the clinical implications of relying on the autorefractor measurements. METHODS: Subjective refraction was carried out on 448 cycloplegic eyes and compared with cycloplegic readings with the Allergan Humphrey 500 autorefractor (448 eyes) and the Nidek AR-1000 autorefractor (160 eyes). Each refraction was followed by clinical visual acuity measurement. The study population comprised 224 healthy students, 107 men and 117 women, with a mean age of 20.6 (SD 1.1) years. RESULTS: Both the Nidek and Humphrey autorefractors measured more negative or less positive refractive values compared with subjective refraction and these biases were statistically significant (Humphrey right eye -0.23 D, p = 0.0001, left eye -0.20 D, p = 0.0001), (Nidek right eye -0.13 D, p = 0.0001, left eye -0.11 D, p = 0.0002). Comparing the results of autorefraction with subjective refraction, the Nidek was better than the Humphrey autorefractor in several ways: a smaller mean difference, better agreement between spherical equivalent values, narrower limits of agreements, and better visual acuity obtained with the autorefraction. On the other hand, the Humphrey autorefractor agreed better with subjective refraction concerning cylinder axis. CONCLUSION: The results show that both autorefractors represent a valuable complement to subjective refraction, but cannot be used as a replacement.
机译:目的/背景:这项研究的目的是估计两种不同的自动验光仪和标准主观验光技术之间的一致性,并评估依靠自动验光仪测量的临床意义。方法:在448例睫状肌麻痹眼上进行主观验光,并与Allergan Humphrey 500自动验光仪(448眼)和Nidek AR-1000自动验光仪(160眼)进行比较。每次验光后都要进行临床视力测量。研究人群包括224位健康学生,107位男性和117位女性,平均年龄为20.6(SD 1.1)岁。结果:与主观折射相比,Nidek和Humphrey自折射器测量的负折射值都更大或更小,这些偏差具有统计学意义(Humphrey右眼-0.23 D,p = 0.0001,左眼-0.20 D,p = 0.0001),( Nidek右眼-0.13 D,p = 0.0001,左眼-0.11 D,p = 0.0002)。将自动验光与主观验光的结果进行比较,Nidek在以下几个方面优于汉弗莱自动验光器:平均差更小,等效球面之间的一致性更好,协议范围更窄以及通过自动验光获得的更好的视敏度。另一方面,汉弗莱(Humphrey)自动验光镜与圆柱轴的主观验光更好地吻合。结论:结果表明,两个自动验光仪代表了主观验光的宝贵补充,但不能用作替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号