首页> 美国卫生研究院文献>The Journal of Physiology >White noise analysis of pace-maker-response interactions and non-linearities in slowly adapting crayfish stretch receptor.
【2h】

White noise analysis of pace-maker-response interactions and non-linearities in slowly adapting crayfish stretch receptor.

机译:起搏器-反应相互作用和非线性在缓慢适应小龙虾拉伸受体中的白噪声分析。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Input-output relations were investigated in the slowly adapting stretch receptor organ of crayfish using a Gaussian white noise length input with a 0.03-12.5 Hz band width and the resulting action potential output. The noise input was presented to the de-efferented receptor in situ, at three mean elongations and at four different amplitudes. The three mean elongations were set within the normal range in vivo, two at the extremes close to the minimum and maximum physiological lengths and the other in the mid-range. With white noise inputs there is a finite probability that the system will be tested in all possible conditions within the chosen band width because white noise has the advantage that it contains, with a finite probability, all possible stimulus wave forms at random. The analysis indicated similarities between the effects of the input variables, namely white noise amplitude and mean elongation. With low input variables the activity was periodic. With larger inputs, impulse rates were higher and irregular. The average length trajectories leading to a spike (i.e. the average stimulus) were either biphasic with high inputs or multiphasic and periodic with lower input variables. The frequency of periodicity increased with mean elongation. Although for a given length and noise amplitude a variety of individual length trajectories preceded spikes, the final biphasic shortening-lengthening average stimulus sequence before a spike was similar in all cases irrespective of the input variables. The number of possible trajectories decreased with increments in the input variables. The standard deviation of length values for each average stimulus was computed and displayed as a function of time relative to the spike. It was first constant, and decreased gradually to a minimum value at the spike reference. Standard deviation values were lower for higher white noise amplitudes and mean elongation. Simple, short-lasting stimulus wave forms in the white noise were isolated and the corresponding responses were computed. Responses were periodic at low input variables and aperiodic with larger inputs and also asymmetric, being larger and briefer for lengthenings than for shortenings. Asymmetries augmented with input increments. Investigation of the interactions between the pace-maker and the white noise effects showed that lengthenings were more effective when they occurred just after a spike while the effectiveness of shortenings was greater just before a spike.(ABSTRACT TRUNCATED AT 400 WORDS)
机译:使用高斯白噪声长度输入(具有0.03-12.5 Hz的带宽)输入小龙虾缓慢适应的拉伸受体器官,研究输入输出关系,并输出动作电位输出。噪声输入以三个平均伸长率和四个不同幅度原位呈现给去射的受体。将三个平均伸长率设定在体内的正常范围内,两个伸长率分别在接近最小和最大生理长度的极限处,另一个在中间范围。对于白噪声输入,在选定带宽内的所有可能条件下测试系统的可能性是有限的,因为白噪声的优势在于,它以有限的概率随机包含了所有可能的激励波形。分析表明输入变量的影响(即白噪声幅度和平均伸长率)之间存在相似性。输入变量低时,活动是周期性的。输入较大时,脉冲率较高且不规则。导致尖峰的平均长度轨迹(即平均刺激)要么是高输入的双相的,要么是低输入变量的多相的和周期性的。周期性的频率随着平均伸长而增加。尽管对于给定的长度和噪声振幅,在尖峰之前有各种单独的长度轨迹,但是在所有情况下,无论输入变量如何,最终的双相缩短-延长-平均拉长刺激序列在所有情况下都是相似的。可能的轨迹数量随着输入变量的增加而减少。计算每个平均刺激的长度值的标准偏差,并将其显示为相对于峰值的时间的函数。它是第一个常数,然后在峰值基准处逐渐减小到最小值。对于较高的白噪声幅度和平均伸长率,标准偏差值较低。隔离了白噪声中简单,持续时间短的刺激波形,并计算了相应的响应。在低输入变量时响应是周期性的,而在较大输入时响应是非周期性的,并且不对称,与缩短相比,加长的响应更大,更简短。输入增量增加不对称性。对起搏器和白噪声效应之间相互作用的研究表明,加长在尖峰之后发生时更有效,而缩短的效果恰在尖峰之前就更大了(摘要截短了400个单词)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号