首页> 美国卫生研究院文献>Chemical Science >Engineering a FRET strategy to achieve a ratiometric two-photon fluorescence response with a large emission shift and its application to fluorescence imaging
【2h】

Engineering a FRET strategy to achieve a ratiometric two-photon fluorescence response with a large emission shift and its application to fluorescence imaging

机译:设计FRET策略以实现具有大发射位移的比例式双光子荧光响应及其在荧光成像中的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Two-photon excitation (TPE) probe-based fluorescence imaging has become one of the most attractive diagnostic techniques to investigate biomolecules and biological events in live cells and tissues. At the current stage most of the TPE-based sensing is reflected by fluorescence intensity changes. Nevertheless the mere altering of intensity could be facilely affected by ambient conditions. On the other hand, TPE probes based on an intramolecular charge transfer (ICT) strategy could solve this problem to some extent with a morphology change-induced emission shift. However their applications are yet constrained due to the inherent limitation of ICT, e.g. the high degree of overlap of two emissions bands and shifts of the TPE maxima. To achieve the desired TPE-based sensing and to circumvent the problems stated above, we adapted a Förster resonance energy transfer (FRET) strategy to develop small molecule ratiometric TPE fluorescent probes. Our FRET-based ratiometric TPE fluorescent probe displays a remarkable emission shift (up to 125 nm) with two well-resolved emission bands. Hence the ratio of these two emission bands could enable the measurement of fluorescence changes more accurately, thus further improving imaging in live cells and deep tissues. To the best of our knowledge, the current reported probe has the largest emission shift among all the small molecule ratiometric TPE fluorescent probes while the maximum TPE wavelength remains unchanged. This work has provided a FRET approach to fabricate novel small molecule ratiometric TPE fluorescent probes that improve imaging in deep tissues.
机译:基于双光子激发(TPE)探针的荧光成像已成为研究活细胞和组织中生物分子和生物学事件的最有吸引力的诊断技术之一。在当前阶段,大多数基于TPE的传感都通过荧光强度变化来反映。然而,仅仅强度的改变可以容易地受到环境条件的影响。另一方面,基于分子内电荷转移(ICT)策略的TPE探针可以通过形态变化引起的发射位移在某种程度上解决此问题。但是,由于ICT的固有局限性,它们的应用仍然受到限制。两个发射波段的高度重叠以及TPE最大值的偏移。为了实现所需的基于TPE的传感并避免上述问题,我们采用了Förster共振能量转移(FRET)策略来开发小分子比例TPE荧光探针。我们基于FRET的比例TPE荧光探针显示出显着的发射位移(高达125 nm),并具有两个分辨良好的发射带。因此,这两个发射带的比率可以使荧光变化的测量更准确,从而进一步改善活细胞和深层组织中的成像。据我们所知,当前报告的探针在所有小分子比例TPE荧光探针中具有最大的发射位移,而最大TPE波长保持不变。这项工作提供了一种FRET方法来制造新颖的小分子比例TPE荧光探针,该探针可改善深部组织的成像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号