首页> 美国卫生研究院文献>Clinical Ophthalmology (Auckland N.Z.) >Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
【2h】

Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision

机译:双眼植入TECNIS Symfony人工晶状体后的视觉质量和性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: To evaluate the visual quality and performance of TECNIS Symfony intraocular lenses (IOLs) implanted with or without micro-monovision approach.>Setting: Chongqing Aier Mega Eye Hospital, Chongqing, China; Daping Hospital of Army Medical University, Chongqing, China.>Design: Prospective study.>Methods: The study comprised 70 cataract patients who had bilateral implantation of TECNIS Symfony extended range of vision IOLs, either with intended micro-monovision (monovision group: 35 patients) or with intended emmetropia (control group: 35 patients). Visual acuity, modulation transfer function (MTF), defocus curve, spectacle independence, and photic phenomena were analyzed 3 months postoperatively.>Results: There was no significant difference between the two groups in binocular uncorrected visual acuity at distance. Mean binocular uncorrected visual acuity at intermediate (monovision: 0.81 dec; control: 0.58 dec) and near (monovision: 0.59 dec; control: 0.30 dec) were significantly better in the monovision group. In the monovision group, the difference of MTF values between the dominant and the non-dominant eyes was not statistically significant and MTF values were within the normal range for both eyes. Spectacle independence at intermediate and near was statistically significantly higher in the monovision group compared to the control group. The incidence of photic phenomena was similar in both groups.>Conclusion: Micro-monovision implantation of TECNIS Symfony IOLs provided a superior range of visual acuity from far to near and higher spectacle independence compared to a control group targeted for emmetropia.
机译:>目的::评估植入或不植入微单眼手术方法的TECNIS Symfony人工晶状体(IOL)的视觉质量和性能。>设置:重庆市爱尔美佳眼科医院,重庆,中国;重庆医科大学附属大坪医院,>设计:前瞻性研究。>方法:该研究包括70例白内障患者,他们均采用双侧植入TECNIS Symfony扩大视野IOL ,既有预期的微单眼(单眼视觉组:35例),也有预期的正视眼(对照组:35例)。术后3个月分析视力,调制传递函数(MTF),散焦曲线,眼镜独立性和光合现象。>结果:两组的远视双眼未矫正视力之间无显着差异。在单视力组中,中度(单视力:0.81 dec;对照组:0.58 dec)和近视(单视力:0.59 dec;对照组:0.30 dec)的平均双眼未矫正视力明显更好。在单眼视觉组中,优势和非优势眼之间的MTF值差异无统计学意义,并且两只眼睛的MTF值均在正常范围内。与对照组相比,monovision组的中,近视眼镜独立性在统计学上显着更高。两组中光合现象的发生率相似。>结论:与对照组相比,TECNIS Symfony IOL的微单眼植入提供了更好的视敏度,从远至近和更高的眼镜独立性。正视眼

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号