首页> 美国卫生研究院文献>World Journal of Orthopedics >Computerized tomography based patient specific blocks improve postoperative mechanical alignment in primary total knee arthroplasty
【2h】

Computerized tomography based patient specific blocks improve postoperative mechanical alignment in primary total knee arthroplasty

机译:基于计算机断层扫描的患者特定区域改善了原发全膝关节置换术中的机械对准

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AIM: To compare the postoperative mechanical alignment achieved after total knee arthroplasty (TKA) using computer tomography (CT) based patient specific blocks (PSB) to conventional instruments (CI).METHODS: Total 80 knees were included in the study, with 40 knees in both the groups operated using PSB and CI. All the knees were performed by a single surgeon using the same cruciate sacrificing implants. In our study we used CT based PSB to compare with CI. Postoperative mechanical femoro-tibial angle (MFT angle) was measured on long leg x-rays using picture archiving and communication system (PACS). We compared mechanical alignment achieved using PSB and CI in TKA using statistical analysis.RESULTS: The PSB group (group 1) included 17 females and seven males while in CI group (group 2) there were 15 females and eight males. The mean age of patients in group 1 was 60.5 years and in group 2 it was 60.2 years. The mean postoperative MFT angle measured on long-leg radiographs in group 1 was 178.23° (SD = 2.67°, range: 171.9° to 182.5°) while in group 2, the mean MFT angle was 175.73° (SD = 3.62°, range: 166.0° to 179.8°). There was significant improvement in postoperative mechanical alignment (P value = 0.001), in PSB group compared to CI. Number of outliers were also found to be less in group operated with PSB (7 Knee) compared to those operated with CI (17 Knee).CONCLUSION: PSB improve mechanical alignment after total knee arthroplasty, compared to CI. This may lead to lower rates of revision in the PSB based TKA as compared to the conventional instrumentation.
机译:目的:比较使用基于计算机断层扫描(CT)的患者特定块(PSB)与常规器械(CI)进行全膝关节置换术(TKA)后获得的术后机械对准。方法:本研究共包括80膝,其中40膝在两个使用PSB和CI进行操作的组中。所有膝盖均由单个外科医生使用相同的牺牲十字形植入物进行。在我们的研究中,我们使用基于CT的PSB与CI进行比较。使用图片存档和通信系统(PACS)在长腿X射线上测量术后股骨胫骨机械角(MFT角)。结果:PSB组(第1组)包括17名女性和7名男性,而CI组(第2组)中有15名女性和8名男性。第一组的患者平均年龄为60.5岁,第二组的平均年龄为60.2岁。第1组在长腿X射线照片上测得的平均术后MFT角为178.23°(SD = 2.67°,范围:171.9°至182.5°),而在第2组中,平均MFT角为175.73°(SD = 3.62°,范围) :166.0°至179.8°)。与CI相比,PSB组术后机械对准明显改善(P值= 0.001)。 PSB(7膝)组与CI(17膝)组相比,异常值更少。结论:与CI相比,PSB改善了全膝关节置换术后的机械对准。与传统仪器相比,这可能导致基于PSB的TKA的修订率降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号