An Overdetermined System of Transform Equations in Support of Robust DCE-MRI Registration With Outlier Rejection

机译:支持离群值剔除的鲁棒DCE-MRI配准的变换方程组

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Quantitative hepatic perfusion parameters derived by fitting dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of liver to a pharmacokinetic model are prone to errors if the dynamic images are not corrected for respiratory motion by image registration. The contrast-induced intensity variations in pre- and postcontrast phases pose challenges for the accuracy of image registration. We propose an overdetermined system of transformation equations between the image volumes in the DCE-MRI series to achieve robust alignment. In this method, we register each volume to every other volume. From the transforms produced by all pairwise registrations, we constructed an overdetermined system of transform equations that was solved robustly by minimizing the L1/2-norm of the residuals. This method was evaluated on a set of 100 liver DCE-MRI examinations from 35 patients by examining the area under spikes appearing in the voxel time–intensity curves. The robust alignment procedure significantly reduced the area under intensity spikes compared with unregistered volumes (P < .001) and volumes registered to a single reference phase (P < .001). Our registration procedure provides a larger number of reliable time–intensity curve samples. The additional reliable samples in the precontrast baseline are important for calculating the postcontrast signal enhancement and thereby for converting intensity to contrast concentration. On the intensity ramp, retained samples help to better describe the uptake dynamics, providing a better foundation for parameter estimation. The presented method also simplifies the analysis of data sets with many patients by eliminating the need for manual intervention during registration.
机译:如果未通过图像配准对动态图像进行呼吸运动校正,则通过将肝脏的动态对比增强(DCE)磁共振成像(MRI)拟合到药代动力学模型而得出的定量肝灌注参数容易出错。在对比之前和之后的阶段中由对比引起的强度变化对图像配准的准确性提出了挑战。我们提出了DCE-MRI系列图像体积之间变换方程的超定系统,以实现稳固的对准。在这种方法中,我们将每个卷注册到其他每个卷。从所有成对配准产生的变换中,我们构建了变换方程的超定系统,该系统通过最小化残差的L1 / 2范数来稳健地求解。通过检查体素时间-强度曲线中出现的尖峰下面积,对35位患者的100例肝脏DCE-MRI检查进行了评估。与未注册的体积(P <.001)和注册到单个参考相位的体积(P <.001)相比,鲁棒的对准程序显着减小了强度峰值下的面积。我们的注册程序提供了大量可靠的时间强度曲线样本。对比前基线中的其他可靠样本对于计算对比后信号增强并由此将强度转换为对比浓度非常重要。在强度梯度上,保留的样本有助于更好地描述吸收动力学,从而为参数估计提供更好的基础。提出的方法还消除了在注册过程中手动干预的需要,从而简化了许多患者的数据集分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号