In view of the settlement problem of transmission tower foundation, the vibration characteristics of transmission towers under wind force are measured experimentally. In this paper, the 110 kV cat head transmission tower of Xi’an Polytechnic University is measured and analyzed. Firstly, the acceleration sensor and meteorological sensor are installed on the tower to collect the vibration response and environment parameters of the tower in real time. Then, an experiment platform is built to simulate the tower settlement, and the vibration response of the tower after settlement is measured in time. Finally, the low-order modal frequencies of the transmission tower before and after settlement under wind force load are extracted by stochastic subspace identification (SSI), and the relationship between modal frequencies of different modes is analyzed via temperature correction. By comparison and analysis, it is obvious that the X-direction modal frequencies before and after settlement under natural wind load are changed, and the change rate increases with the increase of settlement displacement, which can be used as effective evidence for judging the settlement of transmission tower foundation.
机译:针对输电塔地基沉降问题,通过实验测量了输电塔在风力作用下的振动特性。本文对西安工业大学110kV猫头输电塔进行了测量和分析。首先,将加速度传感器和气象传感器安装在塔上,以实时收集塔的振动响应和环境参数。然后,搭建了一个模拟塔架沉降的实验平台,并及时测量了塔架沉降后的振动响应。最后,通过随机子空间识别(SSI)提取了风荷载作用下输电塔沉降前后的低阶模态频率,并通过温度校正分析了不同模态频率之间的关系。通过比较分析,很明显,自然风荷载作用下沉降前后的X方向模态频率发生了变化,且变化率随沉降位移的增加而增大,可作为判断风洞沉降的有效依据。输电塔基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号