Reproducibility of mandibular third molar assessment comparing two cone beam CT units in a matched pairs design

机译:下颌第三磨牙评估的可重复性在配对设计中比较两个锥形束CT单元

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to evaluate the reproducibility of the third molar assessment, comparing five observers and two cone beam CT (CBCT) units. 28 patients, each with two impacted mandibular third molars, were included. Each patient was randomly examined with a Scanora® 3D (Soredex, Helsinki, Finland) CBCT unit in one mandibular third molar region and with a Cranex® 3D (Soredex) CBCT unit in the other region. Five observers with varying CBCT experience assessed all third molars and recorded the following variables: number and morphology of the roots, relation to the mandibular canal in two directions, shape of the canal and whether there was a direct contact between the roots of the molar and the mandibular canal. The radiographic assessments were compared pairwise among all observers for all variables. Wilcoxon's signed-rank test was used to test the differences in observer accordance percentages among the recorded variables in the images from the two units, and kappa statistics expressed interobserver reproducibility. The mean percentages for observer accordance ranged from 65.4 to 92.9 for Scanora 3D and 60.3 to 94.8 for Cranex 3D. There was no significant difference between the observer accordance in the two CBCT units (p > 0.05), except for assessing root flex in the mesiodistal direction, for which the observer accordance was higher for Scanora 3D (p < 0.05). Kappa values ranged from 0.1 to 1.0 for Scanora 3D and from 0.2 to 0.9 for Cranex 3D. For the variable “direct contact”, the interobserver reproducibility was excellent for the two trained radiologists. The two units had almost similar interobserver reproducibility for mandibular third molar assessment. Observer variation existed, and experienced radiologists demonstrated the highest interobserver reproducibility for canal-related variables.
机译:这项研究的目的是评估第三次磨牙评估的可重复性,比较了五个观察者和两个锥形束CT(CBCT)单元。包括28例患者,每个患者的下颌第三磨牙受到两个影响。每位患者均在一个下颌第三磨牙区域内使用Scanora ® 3D(Soredex,芬兰赫尔辛基,芬兰)CBCT装置和Cranex ® 3D(Soredex)CBCT装置进行随机检查在其他地区。五名具有不同CBCT经验的观察者评估了所有第三臼齿,并记录了以下变量:根的数量和形态,在两个方向上与下颌管的关系,根管的形状以及臼齿根和根之间是否存在直接接触。下颌管。在所有观察者中,将所有变量的放射线照相评估成对进行比较。 Wilcoxon的符号秩检验用于检验来自两个单位的图像中记录的变量之间的观察者依从百分比的差异,并且kappa统计数据表示观察者之间的可重复性。对于Scanora 3D,观察者一致性的平均百分比范围从65.4到92.9,对于Cranex 3D,平均百分比从60.3到94.8。在两个CBCT单元中,观察者依从性之间无显着差异(p> 0.05),除了评估近中度方向的根部弯曲度外,对于Scanora 3D,观察者依从性更高(p <0.05)。对于Scanora 3D,Kappa值的范围从0.1到1.0,对于Cranex 3D,Kappa值的范围从0.2到0.9。对于变量“直接接触”,观察者之间的可重复性对于两位受过培训的放射科医生而言非常出色。这两个单位在下颌第三磨牙评估中观察者间的可重复性几乎相似。观察者之间存在差异,经验丰富的放射科医生对与运河有关的变量表现出最高的观察者间可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号